- 14
- 0
- 约3.93万字
- 约 8页
- 2016-11-09 发布于安徽
- 举报
喷雾洗涤冷却室内雾化液滴粒径变化规律的实验的研究.pdf
第 35 卷 第 2 期 中 国 电 机 工 程 学 报 Vol.35 No.2 Jan.20, 2015
396 2015 年 1 月 20 日 Proceedings of the CSEE ©2015 Chin.Soc.for Elec.Eng.
DOI :10.13334/j.0258-8013.pcsee.2015.02.018 文章编号:0258-8013 (2015) 02-0396-08 中图分类号:TQ 021
喷雾洗涤冷却室内雾化液滴粒径
变化规律的实验研究
潘飞,王亦飞,颜留成,郭强强,赵辉,于广锁
(煤气化及能源化工教育部重点实验室(华东理工大学) ,上海市 徐汇区 200237)
Research on Droplet-size Variation in the Spray Quench Chamber
PAN Fei, WANG Yifei, YAN Liucheng, GUO Qiangqiang, ZHAO Hui, YU Guangsuo
(Key Laboratory of Coal Gasification and Energy Chemical Engineering of Ministry of Education (East China University of Science
and Technology), Xuhui District, Shanghai 200237,China)
ABSTRACT: An experimental campaign was conducted to 液滴的 Sauter 平均直径(Sauter mean diameter, SMD)D32 由
study the effect of the flow rate of the gas-liquid two phases on 60 μm 左右上升到了 85 μm ,根据颗粒沉降公式进行计算得
the droplet-size in the spray quench chamber. Droplet-size 到的值与实验值比较,两者趋势一致。
measurements were carried out by a Malvern Spraytec particle
关键词:洗涤冷却室;压力旋流雾化喷头;Sauter 平均直径;
sizer. The result shows that near the nozzle, the liquid flow rate
粒度分布;聚结;多相流
is the key factor that influences the Sauter Mean Diameter,
while being far from the nozzle, both the flow rate of the two 0 引言
phases have an effect, as the Qg increases, the coalescence
efficiency was enhanced, which results in larger D32. It is also 洗涤冷却室是采用激冷流程的气流床煤气化
found the gas flow rate is the significant factor that influences 装置的重要组成部分,目前运行的气化炉洗涤冷却
the Sauter mean diameter (SMD) around the gas outlet, as the 室的洗涤冷却管内存在堵渣问题。文献[1-3]通过实
gas flow rate increases from 300 m3 3
您可能关注的文档
- 1;1 100 kV特高压直流输电用6英寸晶闸管及其设计优化.pdf
- 3种谐波电流注入模式下的磁通切换永磁电机缺相容错控制.pdf
- 700℃超超临界循环流化床锅炉方案设计研究.pdf
- EMI噪声分离网络在电力线噪声分析中的应用.pdf
- Frequency Dividing Droop Controllers With the Function of Voltage.pdf
- GIS中S2OF10作为局部放电特征气体的有效性分析.pdf
- MMC-HVDC联网及孤岛运行状态转换策略.pdf
- Power Generation Systems Using Continuous Blowdown Waste Heat from.pdf
- PWM逆变器的直流侧等效模型研究.pdf
- 一体式双极荷电凝并器试验研究.pdf
原创力文档

文档评论(0)