Permanent Mold Case Study - Tilt Pour - Retainer Seal

* Permanent Mold Case Study – Tilt-Pour Retainer Seal Casting Flow and Solidification Simulation Finite Solutions, Inc. Mold Assembly as received from the foundry. Castings with Gates and Risers Process Data: Casting alloy - A356 Typical pouring temperature 1375 DEG F TO 1435 DEG F Typical tilt time 25 SEC Mold materials MOLD HALVES (CAVITY AND CORE SIDE) 4140 PHT, CORES H-13 HEAT TREATED TO 60 ROCKWELL C Mold preheat temperature 650 DEG F Typical or proposed tilt time SAME AS ABOVE Typical mold spray practices DYCOTE 39 ON CAVITIES, DYCOTE 6 ON GATES AND RISERS, BORON NITRATE RELEASE COA