TEC-101031-4.pptVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
TEC-101031-4

* TEC Controller 實圖 圖18.TEC Controller實圖 * 90mm 65mm 24mm 40x40mm 致冷晶片結合熱管性能測試之冷凝部治具 圖19.致冷晶片結合熱管性能測試之冷凝部治具 * 致冷晶片結合熱管性能測試之冷凝部治具 圖20. .致冷晶片結合熱管性能測試之冷凝部治具實圖 * 實驗架設圖 圖21. 致冷晶片結合熱管性能測試之冷凝部實圖 * Qin W Win W dT Qout W Heat Loss % 24 5 0.2 21.5 10 26 7.09 1.6 23.7 9.4 28 9.18 3 25.5 8.9 30 11.84 4 27.75 7.5 32 14.5 5 30 6.2 34 20 7.54 33 3 36 22 8 34 5 38 28.4 10 36 5.2 40 43.3 12.2 38 5 Table 6. Experiment result for heat pipe performance by using T.E. Cooler ℃ * Fig. 18. Experiment result for heat pipe performance by using T.E. Cooler Dry out at 34W * Table 7. Comparison the maximum heat dissipate of the heat pipe by using water jacket and T.E. Cooler Condenser type Maximum heat dissipate Qmax Heat Loss Qloss % Thermal resistance Test time Water Jacket 34W 10~50 % 0.16 7Hr Auto Control T.E. cooler 34W Within 10% 0.155 3.5Hr Menu Control * To design a heat pipe performance test instrument, the difference between heat dissipate section and heat input section should not too high, the heat loss is general controlled within 10%. This study provide a new method to replace traditional water jacket used on the condenser section of the heat pipe performance test instrument. From performance curve of the T.E., one may easy to control the heat dissipate ability very accuracy. The experiment result shown the Qmax would be the same both at the platforms by using water jacket and by T.E.C,. The thermal resistance calculate difference was within 3% for these two test platforms. It took about 7 hour for automatically control by using the traditional water, while it took only 3.5 hour for manual control by using the T.E.C., the target of this study is expected 20 minutes for the test time. Results * Thanks For Your Attention Tomorrow will be much more better ! * 第十二屆全國熱管會議 12CHPC --中山大學 第十二屆全國熱管會議 12CHPC --中山大學 * 以热电致冷芯片 T.E.C. 取代热管性能量测平台冷凝水套之研究 We are all Family 林唯耕 清华大学工程与系统科学系,台湾 * 熱管性能測試---風冷式 熱管性能測試---水冷式 Water in Water out Tin Tout Heater Watt Meter Variac

文档评论(0)

saa9099 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档