Underinternalpressuresteelpipeandnonferrousmetalpipetestpressureshallbe1.

Under internal pressure steel pipe and nonferrous metal pipe test pressure shall be 1.15 times of design pressure, vacuum pipe test pressure shall be 0200000 mpa. 2. The test should be equipped with pressure relief devices, the set pressure shall not be 1.1 times higher than the test pressure. 3. Before the test, the application of air test, the appropriate test pressure of 0.2 million mpa. 4. Test, it shall gradually increase the pressure, when pressure rose to 50% of the test pressure, such as no abnormalities are found or leak phenomenon, according to 10% of the test pressure booster, step by step per voltage level for 3 minutes, until the test pressure. Should be regulated under test pressure for 10 minutes, and then the pressure drop to design, qualified for foaming agent inspection does not leak. (6) the implementation of the pipeline leak test points Leak test is based on the gas test medium, under the design pressure, using foaming agent, chromogenic agent, gas molecular sensing instrument or other means to check the leak test in the piping system. Implement key points are as follows: 1. Transportation extremely and highly harmful medium and combustible medium pipeline, leak test must be conducted. 2. The leak test should be performed after the pressure test, the test medium appropriate USES air. 3. The leakage test pressure for the design pressure. 4. The leakage test can be combined together. 5. Leak test should be step by step slowly booster, when reach test pressure, and pressure after 10 minutes, adopt the method of besmear brushs neutral foaming agent inspection tour, leak test check the focus is on valve stuffing box, flanged or threaded connection, emptying valve, exhaust valve, drain valve etc. All seal leaks. (7) the implementation of the pipeline vacuum test points Vacuum test for piping system of pumping air into vacuum state, make the internal form a negative pressure pipeline system, to pipeline system of pressurization rate within

文档评论(0)

gangshou + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档