InsulationtestingmethodInsulationtestingmethod

Insulation testing method: to observe the inspection before. 2.15 pipe insulation layer thickness and the flatness of the deviation should be allowed to meet the provisions of this specification table 4.4.8. 3 system hydrostatic test and debug 3.1 heating pipe hydraulic test pressure shall be 1.5 times the working pressure, but shall not be less than 0.6 MPa. Inspection method: under the pressure test pressure drop is not greater than 0.05 MPa within 10 min, and then fell to work under pressure to check, not not leak. 3.2 after the pipeline pressure testing qualified, should be flush. Inspection method, field observation, to water turbidity not qualified. 3.3 should be water, heating the pipe flushing, the commissioning and debugging. When does not have the heating conditions, should be postponed. Inspection method: the building thermal measurement for the return water temperature and pressure at the entrance. 3.4 heating pipes for water pressure test, the test tube on the valve should be open, experiment pipe and the pipe should be blocked. Test method: open and close the valve to check. A. 1.1 finished product protection 5.1 installed pipe shall not be used as crane load and support, and stamped on, or when a fixed point in the construction. 5.2 cover ditch cover plate, should pay attention to protect, not collision damage. 5.3 all kinds of valves and accessory device should be installed protection cover plate, not pollution, smashing touch damage. 6, should pay attention to quality problems 6.1 pipe slope uneven or down the slope. Reason is the hanger spacing is too large, cause local pipeline prolapse, the slope is uneven. Installed on the pipe after open, interface later not straightening. 6.2 hot water heating system after warming, local is not hot. Reason is the main slope is not enough or laying down slope, the system of exhaust system installation position is not correct, the system of air cannot successful eduction, or there are foreign bod

文档评论(0)

cxiongxchunj + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档