- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
LightFastnessTestForInkPrintedMaterials测试指引.
Released Date: Rev. No:Originating Department:Originating Author: PURPOSE AND SCOPEPurpose:The method is to provide instructions to assess the light fastness of ink printed materials.Scope:The method is applicable for all print substrates such as paper, board,plastic films , thin metal plate ( i.e tins) and to all printing processes.EQUIPMENT AND MATERIALS USED IN TESTA xenon arc lamp apparatus with either air cooled or water cooled device;Blue wool references, in accordance with ISO 12040-1997;A grey scale is used for the determination of colour change in accordance withISO 105-A02;Black-Panel-Thermometer, in accordance with ISO 12040-1997;Light source, is a xenon arc lamp with a colour temperature of 5500 K to 6500 K;The filter should completely absorb radiation at wavelengths below 310 nm. The transparency of the glass filters shall be at least 90 % in the range of wavelengths from 380 nm to 700 nm (simulating sunlight behind window glass).SAFETY AND HANDLINGTest personnel must have the basic knowledge and been trained on the materials and equipment used in this test method. Appropriate personal protective equipment (PPE) should be worn if necessary.SAMPLES TO BE TESTEDTest samples should be produced at least 24 hour prior to test. Preconditions test samples for at least 2 hours at room temperature prior to test.PROCEDUREThe test pieces and the blue wool references are mounted together as closely as possible in a well-ventilated testchamber;Use an opaque board with the thickness of 0.5 mmat least to partly cover the test pieces and the blue wool references;The temperature of the test pieces shall not exceed 45℃ as measured by the Black-Panel-Thermometer. Expose the samples to the light in a prescribed manner for a time sufficient to cause adistinct change,which is defined as equal to or less than grade 3 of the grey scale. Take out the test pieces and blue wool reference from the chamber.INTERPRETATION OF RESULTSCompare th
文档评论(0)