- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
SelectiveCoordination
2 * Where is it required again? Article 620 Elevators, Dumbwaiters, Escalators, Moving Sidewalks, Wheelchair Lifts, and Stairway Lift Chairs Article 645 Information Technology Equipment (Critical Operation Data Systems) Article 695 Fire Pumps – campus style building layouts Article 700 Emergency Systems Article 701 Legally Required Standby Systems Article 708 Critical Operations Power Systems (COPS) 2014 NEC Errata: Deleted Figures Oops! State Adoptions of NFPA -70 (NEC) /Technical/Code-Alerts/pages/default.aspx GA adopted the 2014 edition at the beginning of 2015 FL, SC, NC, AL are all still on 2011 TN 2008 with 2009 amendments How does this affect you? Different states will have different requirements and amendments to different code cycles so be aware! Currently in GA, the 2014 code has been adopted. NEC-2014 went to great lengths to standardize their terminology and definitions which may mean slightly different things to older code cycles. NFPA 99-2012 Health Care Facilities Code Added three new sections* to read: Overcurrent protective devices serving the essential electrical system shall be selectively coordinated down to 0.1 seconds. Added three new annex sections** to read: It is important that the various overcurrent devices be coordinated, as far as practicable, to isolate faulted circuits and to protect against cascading operation on short circuit faults. In many systems, however, full coordination could compromise safety and system reliability… * .2.1, .1.1, .1.1 ** A..2, A..1, A.1 Change NFPA 110-2013 Standard for Emergency and Standby Power Systems 6.5 Protection.6.5.1 General.?The overcurrent protective devices in the EPSS shall be coordinated to optimize selective tripping of the circuit overcurrent protective devices when a short circuit occurs.6.5.2 Short Circuit Current. The maximum available short circuit current from both the utility source and the emergency energy source shall be evaluated for the ability to satisfy this co
文档评论(0)