Magne的tic Resonance Imaging I Localization of the MR signa 20_-_Magnetic_Resonance_Imaging_I.pptVIP

Magne的tic Resonance Imaging I Localization of the MR signa 20_-_Magnetic_Resonance_Imaging_I.ppt

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Magnetic Resonance Imaging I Localization of the MR signal Localization of the MR signal Spatial localization, fundamental to MR imaging, requires the imposition of magnetic field inhomogeneities – magnetic gradients superimposed upon the homogeneous and much stronger main magnetic field, which are used to distinguish the positions of the signal in a three-dimensional object (the patient) Conventional MRI involves RF excitations combined with magnetic field gradients to localize the signal from individual volume elements in the patient Magnetic field gradients Magnetic fields with predictable directionality and strength are produced in a wire coil energized with a direct electric current of specific polarity and amplitude Magnetic field gradients are obtained by superimposing the magnetic fields of one or more coils with a precisely defined geometry Magnetic field gradients (cont.) With appropriate design, the gradient coils create a magnetic field that varies linearly in strength vs. distance over a predefined field of view (FOV) Inside the magnet bore, three sets of gradients reside along the coordinate axes – x, y, and z – and produce a magnetic field variation determined by the magnitude of the applied current in each coil set Gradient polarity reversals are achieved by reversing the current direction in the gradient coils Magnetic field gradients (cont.) Two properties of gradient systems are important: The peak amplitude of the gradient field determines the “steepness” of the gradient field (typically 1 to 50 mT/m) The slew rate is the time required to achieve the peak magnetic field amplitude, where shorter time is better (typically 5 to 250 mT/m/msec) Effect on Larmor frequency The gradient is a linear, position-dependent magnetic field applied across the FOV Protons alter their precessional frequency corresponding to their position along the applied gradient in a known and predictable way At the middle of the gradient exists the null, where no change in the

文档评论(0)

xiaofei2001128 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档