Artificial visual prosthesis electrode array and micro-stimulator of in vitro hemolytic.docVIP
- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
PAGE \* MERGEFORMAT 9
Artificial visual prosthesis electrode array and micro-stimulator of in vitro hemolytic
Of: Hao Shubin, Sun Likui, in megabytes piano, Yang Jing
[Abstract] Objective To study the artificial visual prosthesis electrode array and micro stimulator in vitro hemolysis. Methods in accordance with GB / T 16886.12-2005 lt;lt;Biological evaluation of medical devices Part 12: Sample preparation and reference materialsgt;gt; Preparation of the provisions of artificial visual prosthesis electrode array and micro-stimulator test fluid, the test solution according to GB / T 16886.4-2003 lt;lt;Biological evaluation of medical devices Part 4: Selection of tests for interactions with bloodgt;gt; provisions in vitro hemolysis test . The results of the trials, artificial vision implants and micro-electrode array stimulator average hemolysis index was 0.3%. Conclusion The product does not cause hemolytic reactions.
[Keywords:] artificial visual prosthesis; micro-electrode array and micro-stimulator; vitro hemolysis
[Abstract] Objective To study the haemolysis of visual prosthesis microelectrode array and micro-stimulator in vitro.Methods Test extractions was prepared according to biological evaluation of medical devices-Part 12-2005: sample preparation and reference materials and then tested according to biological evaluation of medical devices-Part 4-2005: test selection interaction with blood.Results The average haemolytic index of visual prosthesis microelectrode array and micro-stimulato was 0.3%. Conclusion No hemolysis was showed.
[Keywords:] visual prosthesis; microelectrode array and micro-stimulator; haemolysis in virto
Visual prosthesis is a visual nervous system by stimulating the blind to regain vision in patients with artificial organs. In theory, the visual realization of the prosthesis can be anywhere in the visual pathway to nerve stimulation. In accordance with the implantation of different positions, Basically, the visual
您可能关注的文档
- Art with care geriatric hospital building harmonious relations between doctors and patients Thoughts.doc
- Art with care geriatric hospital building harmonious relations between doctors and patients Thoughts_0.doc
- Artemether on BALB - c mice with CT-26 colorectal cancer tumor suppressor role of the.doc
- Artemisia and Artemisia scoparia volatile oil chemical constituents of Comparative Study.doc
- Artemisia Anatomy of the vessel elements.doc
- Artemisia annua cultivated in the main problems and countermeasures.doc
- Artemisia annua L. and its preparation of volatile components analysis.doc
- Artemisia annua L. in different growth harvest time determination of artemisinin.doc
- Arsenic and retinoic acid on NB4 cell tissue factor and thrombomodulin mRNA and procoagulant activity of.doc
- Artemisia annua rhizosphere microbial dynamics and their relationship with the artemisinin content.doc
- Artillery survey unit of the incidence of low back pain.doc
- Artistic image of the significance of Hua Tuo.doc
- Artistic technique of soft-wen.doc
- Artificial nose in the application of mechanical ventilation and Nursing.doc
- As 'Mr. Oral' Baba Mo.doc
- As 'Xiao seeds' advice.doc
- Artists talk about microblogging.doc
- As 'excellent Simai' prescription.doc
- As a Brand Director how do you market the brand management work-.doc
- As 'PR' innocence.doc
文档评论(0)