厂房结构计算书(国外英文资料)
厂房结构计算书(国外英文资料)
Six an city, Ming dong family furniture
Phase ii workshop
The structure calculation
Review:
School:
Set up:
Volume 1, volume 1
The design is based on the following national specifications:
1, the design of the design of reliability of building structures (gb50068-2001);
Construction load specification (gb50009-2001) (2006)
Building foundation design specification (gb50007-2002)
Design specification for masonry design (gb50003-2001)
Building seismic design specification (gb50011-2010) (2010)
Concrete design specification (gb50010-2001)
Steel structure design specification (gb50017-2003)
Door type newly built light house steel structure technology discipline (CECS 102:2002)
Adopted design software:
The PKPM series developed by the China institute of architecture science.
The load value
Roof:
Dead load:
50 monolayer thick insulation roofing: 0.25 KN / ㎡
Total: 0.25 KN / ㎡
Live load:
0.50 KN / ㎡
Wind load:
N = 50 W = 0.35 KN / ㎡, beta = 1.0, mu by the ground roughness class B.
Snow load: 0.55 KN / ㎡
Engineering name: mj-1
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
Date: 7/6/2011
Time: 6:39:42
Design principal basis:
Construction load specifications (GB 50009-2001);
Design code for earthquake resistant design (GB 50011-2001);
Design specifications for steel structure (GB 50017-2003);
Technical regulations on the steel structure of light house steel (CECS 102:2002);
Results output
-- total information --
Structural type: the door type rigid housing steel structure
Design specification: according to the door type rigid housing steel structure technology regulation computation
Structural importance factor: 1.00
Number of nodes: 31
Columns: 10
Beam number: 24
Support constraints: 5
Total number of standard sections: 11
Live load calculation information: consider the disadvantage of live load
Wind load calculation information: calculate wind load
Steel: Q345
The beam self-recomputation information: the pillar beam self-weighted is