交流电动机交接试验标准(国外英语资料)

交流电动机交接试验标准(国外英语资料) AC motor transfer test standard ________________________________________ 5 alternating current motor test standard Article 5.0.1 the test items for AC motors are as follows: I. insulation resistance and absorption ratio of measuring coil; Two 、 measuring DC resistance of coil; Three 、 AC voltage withstand test of stator coil; Four AC voltage withstand test of rotor winding of winding motor; Five 、 AC voltage test of rotor coil of synchronous motor; Six. Measure the insulation resistance of variable resistor, starting resistor and de excitation resistor; Seven. Measure the DC resistance of variable resistors, starting resistors, and de magnetic resistors; Eight. Measure the insulation resistance of motor bearings; Nine. Check the polarity of stator coil and the correctness of its connection; Note: (1) motors under 40 kW are tested in accordance with item first, sixth of this article; (2) AC motors installed in underground mines or other places with explosion hazards can not be AC withstand voltage test. Article 5.0.2 insulation resistance and absorption ratio of measuring coil. A rated voltage below 1000 volts, room temperature insulation resistance should not be less than 500 billion ohm; rated voltage of 1000 volts and above, the insulation resistance near the operation temperature value of the stator coil should be not less than 1 / kV megohm, rotor coil should be not less than 500 billion / kV Europe; insulation resistance temperature conversion can refer to appendix three; The absorption ratio shall be measured at two or more than 1000 volts, and the absorption ratio shall be no less than 1.2, and shall be measured separately when necessary. Note: (1) before the AC withstand voltage test, the insulation of the coil shall meet the requirements of this clause one or two; (2) AC withstand voltage test of the motor, when its insulation resistance value is close to the operating temperature (epoxy powder mica absolutely The edge motor is not less

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档