安全装置常见故障和处理方法(国外英文资料)
安全装置常见故障和处理方法(国外英文资料)
Displacement sensor, weighing sensor, light screen sensor, flat layer sensor, velocity coder, etc.
The third part
Common failures and handling of safety devices
one
Stop circuit failure
The phenomenon of
Stop relay
(
Voltage relay
)
Dont suck.
why
In the emergency power line of the elevator, the coils of the stop relay are generally closed to the following safety switches
In series, such as bottom-hole emergency stop switch, speed limiter switch, safety window switch, car top urgent stop switch, sedan chair
Stop switch, safety clamp switch,
Phase-sequence relay contact
The towing motor relay contact, owing to magnetic relay
Contact,
Steel band switch, etc.,
Any of these switches will break off the relay coil
Electrical discharge, which makes the control circuit of the elevator fail to start.
Processing method
1.
Check for the cause of the failure of the safety switch and repair it.
2.
Maintain safety switch on a regular basis
As a reliable. In operation, it is absolutely forbidden to use wire short switch contact, which causes the elevator to run.
2
Limit switches do not fall
The phenomenon of
The elevator is at the end of the pole and the car is not able to touch the limit switch.
why
The tension between the car is too large or the pressure is less than the limit
On the switch ratchet, the switch cant pull down.
Processing method
Adjust the gap between the car and the wheel, and make it suitable for the production of wire rope
Theres enough tension to transfer to the limit switch.
Adjust the required
1.
When the elevator is slower than the end point,
Limit switch should be sensitive.
2.
Limit switch
When the action is done, the distance between the lower and upper end of the car is the distance from the upper and lower part of the car
50
~
200 mm
.
3
Door interlock switch failed
The phenomenon of
The door lock relay is closed and closed.
why
Because the lock relay coil is connected to the door lock of the various floors, th
您可能关注的文档
- 修改封装的ghost部分文件(国外英文资料).doc
- 修改我的电脑系统属性(国外英文资料).doc
- 修改注册表定制IE的internet选项安全设置(国外英文资料).doc
- 假显卡常用核心,识别假显卡(切勿用于作假用途)(国外英文资料).doc
- 修改游戏存档(国外英文资料).doc
- 光伏成本核算(国外英文资料).doc
- 充油耐震精密压力表,低成本压力表,绝压表(5寸表),差压表(5寸表)(国外英文资料).doc
- 光电开关(国外英文资料).doc
- 光电接近开关(国外英文资料).doc
- 光盘刻录注意事项(国外英文资料).doc
- 福莱特玻璃集团股份有限公司海外监管公告 - 福莱特玻璃集团股份有限公司2024年度环境、社会及管治报告.pdf
- 广哈通信:2024年度环境、社会及治理(ESG)报告.pdf
- 招商证券股份有限公司招商证券2024年度环境、社会及管治报告.pdf
- 宏信建设发展有限公司2024 可持续发展暨环境、社会及管治(ESG)报告.pdf
- 品创控股有限公司环境、社会及管治报告 2024.pdf
- 中信建投证券股份有限公司2024可持续发展暨环境、社会及管治报告.pdf
- 洛阳栾川钼业集团股份有限公司环境、社会及管治报告.pdf
- 361度国际有限公司二零二四年环境、社会及管治报告.pdf
- 中国神华能源股份有限公司2024年度环境、社会及管治报告.pdf
- 广西能源:2024年环境、社会及治理(ESG)报告.pdf
文档评论(0)