电力系统自动装置简答(外国英文资料)
电力系统自动装置简答(国外英文资料)1, parallel operation: random variation in the power system load, in order to guarantee the power quality, and meet the requirements of safety and economic operation, often will stop and run operation of generator, put a stay in no-load generator after the necessary adjustment in the system, under the condition of satisfy in the switch and the system operation, the operation process is called parallel operation.2, penecontemporaneous juxtaposition: stay and generator excitation, first to make the generator set up voltage, adjust the voltage and frequency of the generator, with the system voltage and frequency is close to equal, choose the right time to make the generator voltage and system voltage on the phase Angle difference is close to 0 o close tied for circuit breaker, the generator power grid.3, the same period since the juxtaposition: approach without excitation, synchronous speed generator into system, then to the generator and excitation, in the original regulated torque and synchronous torque under the action of the generators into synchronization, complete with operation.Coordinate the same period: it is the condition of generator grid. The coordinate points of the same period are the same as the same, the same power frequency, the same voltage.Slide difference, slide difference frequency, slip cycle: slip difference: the difference between the voltage and voltage of the generator on both sides of the circuit breaker and the system voltage. Slip cycle: the parallel circuit breakers on either side of the generator voltage and system voltage phase Angle difference between the time required for 360 °.6, constant step forward phase Angle is juxtaposition: at the same time before the Ug and the Ux, the constant Angle at the same Angle is the same as the same as the same.Whole step voltage, sinusoidal voltage, linear whole step voltage: automatic parallel device, test and coordinate condition, contain voltage of synchronous condition informati
文档评论(0)