查看更多
变频器应用故障200例(国外英文资料)
变频器应用故障200例(国外英文资料)
200 cases of frequency converter applications
Book analyzes the frequency converter in the work of all kinds of fault elimination method and frequency converter of specific engineering application, cases are from engineering practice, the field of frequency converter fault has great reference value.
The book is divided into nine chapters: chapter 1, frequency changer, and maintenance of current failure. Chapter 2, the maintenance of a transformer overloaded ground fault; Chapter 3, the voltage of the frequency changer, the maintenance of overvoltage failure; Chapter 4, the maintenance of the converters electromagnetic interference failure; Chapter 5, the maintenance of the transformers overheating failure; Chapter 6, the maintenance of the frequency converter communication control failure; In chapter 7, the frequency changer does not report the maintenance of the failure. Chapter 8, the frequency converter parameter sets up the maintenance of the failure; Chapter 9, the converter industrial application case.
This book is used by the enterprise field engineers, and also as a reference book for teachers and students of technical colleges.
preface
Chapter 1 the frequency changer in the maintenance of current failure
The cause of the current failure of the frequency converter
1.1.1 converter overcurrent causes
The 1.1.2 converter started the current tripping
1.1.3 impact load causes current tripping
The 1.1.4 converter parameter is improperly set or out-of-control
The 1.1.5 load does not normally cause the current tripping
A short circuit of 1.1.6 circuit caused the current tripping
The internal circuit device of the 1.1.7 converter has damaged the current tripping
1.2 converter circuit failure case
The frequency of the case 1 converter rises to 16Hz over current
Case 2 motor short circuit causes the converter to overcurrent
Case 3 Fuji converter starts over current
Case 4 compensates for improper starting of current
Case 5 converter starting motor j