客房缺陷Sample room checklist with photos - September
CHECK LIST
Date:
Checked By:
Villa Entry
OPS Project
Items Remarks Date Inspected: Inspected By: Date Inspected: Inspected By:
All excess paint to be removed from access walkway.
Remove all excess paint overspray on wall from bamboo screen treatment at entry doorway.
No ground/earth wire provided to light fitting.
Exposed cabling, need to cover by installing wires in conduit and paint to match wall finish color.
Entry door does not keep rain water out, floor very slippery when water inside and door rattles in wind at night and is disturbing.
To provide a weather strip on bottom of door and a seal to be applied to the door frame to prohibit rattling in wind.
CHECK LIST
Date:
Checked By:
Mechanical Room
OPS Project
Items Remarks Date Checked By: Date Checked By:
Aircon unit not installed properly, it is at an angle across the plant room and therefore air flow across the coils is not as good as it should be, additionally the hot exhaust air is re-circulated inside the room and decreases efficiency of the unit.
No cover on MATV junction box, individual circuits are not labeled either at the terminal box or inside the guest room wall plates for ease of identification.
Exposed wiring and terminations to be replaced and all terminations made in approved junction boxes.
Electrical switch board circuits not labeled and no safety cover plate with circuit breakers identified.
Voice and Data cabling not installed properly (blue cable).
Hot and Cold water supply isolation valves not labeled.
Air-conditioning screen not installed properly.
CHECK LIST
Date:
Checked By:
Room Inside/ Main Living Room
OPS Project
Items Remarks Date Checked By: Date Checked By:
Paint marked and stained on the wall beside TV.
Water damage around window beside TV, suspect poorly installed window frame - to be inspected and addressed.
TV cabinet damage.
Mini b