交流电动机交接试验标准(外国英语资料)
交流电动机交接试验标准(国外英文资料)
Test standard AC motor transfer
________________________________________
Test standard for transfer of 5 AC motor
Test items of article 5.0.1 of AC motor is as follows:
A measuring coil, insulation resistance and absorption ratio;
Two, the coil DC resistance measurement;
Three, AC withstand voltage test on stator coil;
AC withstand voltage test, four winding motor rotor coil;
Five, the rotor coil synchronous motor AC voltage test;
Six, insulation resistance measurement variable resistor starting resistor and deexcitation resistor;
Seven, DC resistance measurement variable resistor starting resistor and deexcitation resistor;
Eight, measure the insulation resistance of motor bearing;
Nine, check the polarity of the stator coil and its connection is correct;
Note: (1) motor 40 kW, the test was conducted according to the article first, sixth;
(2) AC motor installed in the underground coal mine or other explosive sites can be AC voltage withstand test.
Article 5.0.2 measuring coil insulation resistance and absorption ratio.
A rated voltage below 1000 volts, room temperature insulation resistance should not be less than 500 billion ohm; rated voltage of 1000 volts and above, the insulation resistance near the operation temperature value of the stator coil should be not less than 1 / kV megohm, rotor coil should be not less than 500 billion / kV Europe; insulation resistance temperature conversion can refer to appendix three;
Two, 1000 Volts above the motor should measure the absorption ratio, absorption ratio should not be less than 1.2, it is necessary to measure the phase.
Note: (1) make AC withstand voltage test, coil insulation should meet the requirements of paragraph one or two;
(2) AC motor test qualified, when the value of the insulation resistance near the operating temperature (epoxy powder mica vast
Margin of the motor is at room temperature under) is not lower than the rated voltage 1 / kV megohm, can be put into operation. but