电工进网考试A卷习题以及答案(国外英文资料).docVIP

电工进网考试A卷习题以及答案(国外英文资料).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
电工进网考试A卷习题以及答案(国外英文资料)

电工进网考试A卷习题以及答案 A single choice (options for each question, only one of the most to do a wrong, each question, the election or not is 0 points, a total of 40 points) 1. the insulation level of power equipment in neutral point direct grounding system shall be considered in accordance with (A). A. phase voltage 2. voltage quality is divided into voltage allowable deviation, three-phase voltage allowed imbalance degree, (A) and so on. A. frequency allowable deviation 3. the cooling device of the transformer is acting (A). A. heat dissipation The 4. current transformer is a small current that changes the current in a high voltage system or a B in a low voltage system to a low voltage standard. B. high current The nominal voltage of the two side of the three-phase transformer connected by the 5. winding Yy is equal to (C). C. transformer rated capacity divided by two times the rated current of 3 times the square root of the side The ideal condition for the 6. transformers to operate in parallel is that the voltage ratio of the transformer is equal, the impedance voltage of the transformer is equal, and (B). The B. transformer has the same set of group labels 7. pairs (B) transformers, whether or not there are persons on duty, should be visited every hour. B. forced oil circulation, water cooling or air cooling The phase number of 8. transformers is generally divided into two kinds (A). A. single phase and three-phase 9. after tens of thousands of volts or hundreds of thousands of volts of high voltage power can be delivered to (C), they must pass through different step-down transformers to reduce the voltage to different levels of voltage to meet the needs of various loads. C. load area 10. the iron core of the transformer is made of laminated silicon steel with good magnetic conductivity, and can (C) the iron loss of the transformer. C. decrease The oil conservator of the 11. transformer is located above the transformer oil tank, and the same as through gas relay (A). A

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档