电工进网考试A卷习题以及答案(国外英文资料)
电工进网考试A卷习题以及答案
A single choice (options for each question, only one of the most to do a wrong, each question, the election or not is 0 points, a total of 40 points)
1. the insulation level of power equipment in neutral point direct grounding system shall be considered in accordance with (A).
A. phase voltage
2. voltage quality is divided into voltage allowable deviation, three-phase voltage allowed imbalance degree, (A) and so on.
A. frequency allowable deviation
3. the cooling device of the transformer is acting (A).
A. heat dissipation
The 4. current transformer is a small current that changes the current in a high voltage system or a B in a low voltage system to a low voltage standard.
B. high current
The nominal voltage of the two side of the three-phase transformer connected by the 5. winding Yy is equal to (C).
C. transformer rated capacity divided by two times the rated current of 3 times the square root of the side
The ideal condition for the 6. transformers to operate in parallel is that the voltage ratio of the transformer is equal, the impedance voltage of the transformer is equal, and (B).
The B. transformer has the same set of group labels
7. pairs (B) transformers, whether or not there are persons on duty, should be visited every hour.
B. forced oil circulation, water cooling or air cooling
The phase number of 8. transformers is generally divided into two kinds (A).
A. single phase and three-phase
9. after tens of thousands of volts or hundreds of thousands of volts of high voltage power can be delivered to (C), they must pass through different step-down transformers to reduce the voltage to different levels of voltage to meet the needs of various loads.
C. load area
10. the iron core of the transformer is made of laminated silicon steel with good magnetic conductivity, and can (C) the iron loss of the transformer.
C. decrease
The oil conservator of the 11. transformer is located above the transformer oil tank, and the same as through gas relay (A).
A
您可能关注的文档
- 急性肺水肿(国外英文资料).doc
- 恩施州扶贫开发工作的调查与思考(国外英文资料).doc
- 恒压供水(一拖一)(国外英文资料).doc
- 息肉电凝切除术后综合征回顾分析(国外英文资料).doc
- 情境战略 指引未来的战略系统特征(国外英文资料).doc
- 悬挂(国外英文资料).doc
- 情境战略----指引未来的战略系统特征(国外英文资料).doc
- 惠州市2010届高三第一次高考模拟考试(国外英文资料).doc
- 感恩的心 主题班会(国外英文资料).doc
- 懒床的坏处(国外英文资料).doc
- 2026学年上海市金卫中学教师招聘参考题库附答案解析.docx
- 2026宁夏天地奔牛实业集团有限公司全球校园招聘备考题库附答案解析.docx
- 2026学年上海市金卫中学教师招聘备考题库附答案解析.docx
- 2026学年上海市金卫中学教师招聘参考题库附答案解析.docx
- 2026奇瑞汽车博士校园招聘参考题库附答案解析.docx
- 2025年上交所董秘试题及答案.docx
- 2026宁夏天地奔牛实业集团有限公司全球校园招聘参考题库附答案解析.docx
- 2026宁夏石油分公司校园招聘5人参考题库附答案解析.docx
- 2026奇瑞汽车博士校园招聘备考题库附答案解析.docx
- 大数据环境下的测试开发工作策略及规划.docx
原创力文档


文档评论(0)