Ct球管(国外英语)
Ct球管(国外英语资料)
The principle, use and maintenance of the CT (X-ray) bulb
Liu junsong chang guang-chang medical science and technology co., LTD. (zhuhai 519060)
Abstract: at present, the CT imaging has become indispensable to modern hospital routine diagnostic technology, the core technology of the CT tube ball is the most expensive consumable, so the system to understand the principle of CT bulb, correctly grasp the using method and the common faults, careful maintenance and prolong its service life is a very meaningful work.
Keywords: cT replacement tube maintenance
Article number: 1006.6586 (2005) 05 048-03: TNll document identification code: B
CT (Computed Tomography) or computer Tomography, is the bodys internal organs anatomical morphological structure of the main means of imaging system, especially to check with density and morphology changes of disease sensitive lesions, caused by it revolution promoted the rapid development of medical imaging diagnosis technology.
CT machine composed mainly of x line (x - ray) system, signal receiving system (detector), computer processing system, signal processing and image reconstruction and ancillary equipment (monitor, camera, etc.), its core device is cT tube ball. , the work of the box , the box
The structure of a CT ball tube
CT tube core? Pipe sleeve? The high voltage circuit and the cooling system are composed of several parts. The core is composed of cup cathode filament, rotating anode tungsten target, high speed bearing, auxiliary heat sink, etc.
The principle of the cT tube
CT tube is actually a big high vacuum cathode ray diode, is to produce X-ray system, its working process is: by heating for the 12 v current on cathode filament, and generate free electrons, then to the Yin and Yang with 40 a 150 kv high voltage electric potential difference spurt, under the high pressure electric field driven, active free electron beam, the cathode speed bump
The anode of the anode is struck by the anode, and the energy conver