三菱电梯检修实例(Mitsubishi elevator maintenance instance)

三菱电梯检修实例(Mitsubishi elevator maintenance instance) MITSUBISHI elevator GPS fault elevator maintenance examples share: 124.14.228.*, 1 floor Case analysis of elevator fault 01 Fault phenomenon: A hospital two MITSUBISHI GPS-I elevator, when there is a call, in an elevator group control in response to the call, the call is not disannul, only another elevator also in response to the call, just eliminate no.. That is to say, for any outside call, two group control elevators should respond once. Treatment process: 1. check the floor settings, single staircase / group control settings in the elevator software, and find no problems; 2. check outside call connection and correct wiring. 3. disconnect the power supply of the group control cabinet, and then disconnect the main power supply of one of the elevators, then another elevator works normally. 4. disconnect the group control panel power supply, and respond to any call or two elevators. 5., through the above test, it can be concluded that the independent operation of the two elevators is normal, the problem should be in the group control part, or the communication between the group control and the individual ladder; 6. check and change (or replace) the group control computer board, without any problems; 7. when inspecting the fiber optic cable, it is found that the two parts of the optical fiber are respectively bundled on the frame of the control cabinet, and the radian of the bent part is too small. Replace two optical fiber communication cables, and lift back to normal. This case inspires: In this case, two elevators share an outside calling signal, that is, the calling signal is a set of buttons and two sets of display forms. The outside calling signals are respectively communicated with the group control computer board after entering the P1 main computer board of the two elevator, and then passing through the fiber optic cable. When the communication fails, the two elevators are in a separate state of operation. Al

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档