电压互感器的原理(The principle of voltage transformer)

电压互感器的原理(The principle of voltage transformer) The principle of voltage transformer The principle of the voltage transformer is that the ratio of the high voltage to the voltage is equal to the number of windings on the high side of the voltage divided by the number of turns on the low-voltage side, that is, the ratio of the voltage to the number of turns. While the number of primary side coil current transformer is little, generally one wire, two side put many turns, so the voltage transformer principle analysis, if an induction to the low voltage, then the two side if open you will feel a very high voltage and voltage. The two side is not more than 2000V, so the two side is strongly not open. On the other hand, because of one and two are connected in series to form a loop, so a voltage current resistance to side induction is equal to a side flow resistance, current two side is equal to the voltage divided by two side two side feel, when when one side of the large current flows, because the current voltage resistance * primary side sensing to equals one side flow, so a voltage increases, a voltage increases two times to the induction voltage is increased, and the two side current is equal to the voltage divided by two side resistance, so the current two secondary side induction to also increases. Voltage transformer wiring mode is very common, the following are common: 1, a single phase voltage transformer is used to measure the relative voltage of the ground or the phase to line voltage 2, using two single-phase transformer with incomplete star, also known as V - V junction, used to measure each phase voltage, but can not be measured relative to the voltage, widely used in the 20KV below the neutral point ungrounded or discharging coil grounding grid. 3, using three single-phase three winding voltage transformer of YN, YN, d0 or YN, y, d0 connection form, is widely used in 3~220KV system, the second winding is used for measuring the line voltage and relative auxil

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档