网站大量收购闲置独家精品文档,联系QQ:2885784924

02砌体结构规范勘误)(02 masonry structures, specifications, Corrigendum)).doc

02砌体结构规范勘误)(02 masonry structures, specifications, Corrigendum)).doc

  1. 1、本文档共15页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
02砌体结构规范勘误)(02 masonry structures, specifications, Corrigendum)) Opinions on the design code for masonry structures Source: Zhang Haishuns Journal Code for design of masonry structures in the national standard management group, Masonry Structure Construction Engineering Standards Association Committee Chinese November 2004 General Conference on Application of basic theory and Engineering Conference and the December 2005 National masonry structure organized during the code for design of masonry structures GB50003 working group members and the Committee of experts of masonry structure has two times feedback code design of masonry structures GB50003-2001 enacted since were fully discussed. These include feedback due to local changes in the mandatory provisions requirements of relevant provisions in terms of the cause, the definition of certain provisions is not clear enough, some provisions are to be improved, and the terms and provisions of text expression errors and omissions. At the same time theory system construction standard design of masonry structure in GB50003 and further improve the content and principles of future revisions of the standard, especially in recent years, application of new wall materials and structures are discussed and deployment. The following only comments on the feedback involved in the definition of the article is not clear enough or accurate, or not comprehensive and wrong, and so on, given the consensus of the discussion. And publish as a unified treatment opinion. I. opinions on Relevant Issues concerning feedback (1) description of strength adjustment of masonry; 1, 3.2.1 4 section of grouted masonry strength FG 1) adjust only one of the f. 2) 3.2.1-3, note 2 and 3, may not be reduced when the provisions of article 6.2.10 are met. 3) to adopt Mbxx type cement mortar, take gamma a=1.0. 2, 5.2.1 in the F - Masonry compressive strength design value, may not consider the provisions of the second paragraph of article 3.2.3. 3, 5.5.1 in the

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档