02砌体结构规范勘误)(02 masonry structures, specifications, Corrigendum))
Opinions on the design code for masonry structures
Source: Zhang Haishuns Journal
Code for design of masonry structures in the national standard management group, Masonry Structure Construction Engineering Standards Association Committee Chinese November 2004 General Conference on Application of basic theory and Engineering Conference and the December 2005 National masonry structure organized during the code for design of masonry structures GB50003 working group members and the Committee of experts of masonry structure has two times feedback code design of masonry structures GB50003-2001 enacted since were fully discussed. These include feedback due to local changes in the mandatory provisions requirements of relevant provisions in terms of the cause, the definition of certain provisions is not clear enough, some provisions are to be improved, and the terms and provisions of text expression errors and omissions. At the same time theory system construction standard design of masonry structure in GB50003 and further improve the content and principles of future revisions of the standard, especially in recent years, application of new wall materials and structures are discussed and deployment. The following only comments on the feedback involved in the definition of the article is not clear enough or accurate, or not comprehensive and wrong, and so on, given the consensus of the discussion. And publish as a unified treatment opinion.
I. opinions on Relevant Issues concerning feedback
(1) description of strength adjustment of masonry;
1, 3.2.1 4 section of grouted masonry strength FG
1) adjust only one of the f.
2) 3.2.1-3, note 2 and 3, may not be reduced when the provisions of article 6.2.10 are met.
3) to adopt Mbxx type cement mortar, take gamma a=1.0.
2, 5.2.1 in the F - Masonry compressive strength design value, may not consider the provisions of the second paragraph of article 3.2.3.
3, 5.5.1 in the
您可能关注的文档
- 幕墙工程质量通病和其防治措施.doc
- 幕墙预埋件施工工艺.doc
- 幕墙立柱和立柱连接设计.doc
- 尼康曲线安装和使用.doc
- 幕墙中光污染问题.doc
- 年入7位数营销信模板案例与赚钱秘密.doc
- 年轻,是我们张扬资本.doc
- 平安与谐校园创建规划.doc
- 平乐乡展厅布置和策划方案.doc
- 平南土白话 2.doc
- 某某单位2024年党建工作总结及2025年工作计划.doc
- 某某市发改委关于2024年度落实党风廉政建设工作责任制情况的报告.doc
- 某某局2024年全面从严治党和党风廉政建设工作总结.doc
- 某某区财政局2024年法治政府建设总结及2025年工作谋划.doc
- 2024年党管武装工作述职报告2篇.doc
- 2024年度国企党委书记抓基层党建工作述职报告3篇.doc
- 公司党委书记2024年述职述廉报告.docx
- 2024年度乡镇党委领导班子民主生活会(四个带头)对照检查材料.doc
- 市医疗保障局关于2024年法治政府建设工作情况的报告.docx
- 市民政局党组2024年巡察整改工作情况报告.docx
文档评论(0)