《铁路技术管理规程》普速版 第七章 2014.7(Rail technical management regulations speed version of the seventh chapter 2014.7).doc

《铁路技术管理规程》普速版 第七章 2014.7(Rail technical management regulations speed version of the seventh chapter 2014.7).doc

  1. 1、本文档共10页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
《铁路技术管理规程》普速版 第七章 2014.7(Rail technical management regulations speed version of the seventh chapter 2014.7) The seventh chapter is power supply and water supply Traction power supply 196th, in order to maintain the good technical state of traction power supply equipment and ensure the safe operation of the traction power supply system, the power supply section and other power supply maintenance institutions should be set up. The jurisdiction of power supply maintenance institutions shall be determined according to the conditions of the line and power supply equipment. Traction power supply equipment includes substation equipment (transformer substation, open and shut substation, transformer substation), contact network and telecontrol system. 197th traction power supply equipment shall ensure reliable power supply for uninterrupted driving. The traction power supply capacity should be in line with the transportation capacity of the line to meet the required train weight, train density and operation speed. The nominal value of the contact voltage is 25kV, the maximum operating voltage is 27.5 kV, the short-time (5 min) maximum working voltage is 29 kV, and the minimum operating voltage is 19 kV. Traction substation must have double power supply and double circuit power supply. Traction transformer adopts fixed standby mode and has automatic switching function. When a traction substation is out of power, the adjacent traction substation can supply power over the district. During operation, the average power factor is not less than 0.9. The 198th traction power supply dispatching system should have the condition of remote real-time monitoring of traction power supply equipment, and be centralized and unified management of the dispatching system. The 199th sections of the contact network should be taken into account, such as maintenance, power failure, convenience and reduction of the scope of power failure, and full consideration of the normal operation of the train an

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档