浅析地下室除湿施工技术 编 制 人: 赵世华 申请职称: 工作单位: 长春建筑学院 申报日期: 二零一三 年 九 月 九 日 浅析某工程地下除湿施工技术 赵世华 长春建筑学院 摘要:目前大部分在施综合建筑都配有地下车库,施工过程中每当夏季或雨季,由于排水、通风系统没有正式启用,雨水和试压泄水再加上自然环境湿度较大,都会造成地下区域装饰和机电设备的发霉或腐蚀,此现象造成成品保护困难进而增加施工成本及管理成本。本文对某建筑夏季地下施工期间除湿办法阐述。 关键词:复杂地下空间的除湿方法及益处、除湿设备。 Analyses some engineering dehumidification construction technology of underground Abstract:Currently most comprehensive buildings are equipped with an underground garage. The underground area can cause mold or corrosion of decoration , mechanical and electrical equipment on account of drainage, ventilation system was not the official opening as to as rain and pressure drainage combined with natural environmental humidity is bigger in the summer or the rainy season in the execution , even more serious is that the phenomenon is difficult to finished product protection, which further increases the construction cost and management cost. In this paper,the dehumidification of a summer underground buildings during construction method in this paper. Keywords:Complex underground space,Dehumidification method Dehumidification equipment 一、工程描述 某一综合性酒店,主楼主要的使用功能为酒店房间、剧院。总建筑面积为83690㎡,高度128.8米。地上部分主要由4层高裙楼及28层的塔楼所组成,建筑面积约为5万平方米。主体框架剪力墙结构,主楼采用桩筏基础,裙楼采用桩筏基础和筏板基础,桩为挖孔灌注桩,基底标高为-10.65米,局部深度-18.54米。 二、湿度概括 众所周知,人体需要在一定适宜的温湿度下才能感觉舒适,一定的温湿度不仅仅对人体对各行各业的影响都是至关重要的,随着人们对于环境了解不断深入,所以湿度的控制才会应用的更加广泛。 湿度的影响 我们对温湿度的直接判断来源于我们所处环 境舒适度的感知,通常我们会通过加热、冷却、加湿或者增减衣物来提高我们的舒适感。不仅仅是我们,人类很多物资材料和制造产品同样会受到温湿 度的影响,当贮存或工艺条件不理想时,损坏、腐蚀、生产故障就会发生,直接影响我们的生产效率和产品质量。 1)过高的湿度不利于人体舒适感和健康。 在任何气温条件下潮湿的空气对人体都是不利的。研究表明,湿度过大时,人体中一种叫松果腺体分泌出的松果激素量也较大,使得体内甲状腺素及肾上腺素的浓度就相对降低,细胞就会“偷懒”,人就会无精打采,萎靡不振。长时间在湿度较大的地方工作、生活,还容易患湿痹症。空气湿度过大时,有利于一些细菌和病毒的繁殖和传播。科学测定,当空气湿度高于 65%时,病菌繁殖滋生最快,当相对湿度在45%-55%时,病菌死亡较快。 人体致死的高温指标与空气湿度也有很大关系。当气温和湿度高达某一极限时,人体的热量散发不出去,体温就要升高,以致超过人体的耐热极限,人即会死亡。我国规定灾害性天气标准为,长江以南最高气温高于38℃,或者最高气温达35℃,同时相对湿度高于61%;长

文档评论(0)

1亿VIP精品文档

相关文档