消防保养(Fire maintenance)
Precautions in maintenance inspection
The purpose of maintenance inspection is to check out the problems existing in the fire protection system, but we must avoid any damage or misjudgment due to our negligence and ignorance. The first response to the entire fire control system to have a general understanding, especially the linkage system, do not know the equipment do not start before the start, notify the person to guard, because otherwise we start the pump, air conditioning, elevator, strong power cut, there may also be some other equipment, may cause damage to their work, passive. During automatic testing, isolate the equipment that does not want to start automatically. Here are some considerations for system checking.
I. automatic alarm system
This system is generally familiar to people, and will not cause serious accidents, but some places should also pay attention to:
1 、 the field equipment such as the test detector is not calibrated or positioned incorrectly on the drawings, and some Chinese characters are incorrect or incomplete.
2, the controller should first clean shutdown, and then use the fine brush gently sweep dust. Where the plate must be removed, remember to assemble and disassemble the position.
3, pay attention to the controller linkage formula and the black box record is normal.
Two fire hydrant system and water spraying system
This system is generally less contact with people, if not properly handled, there will be serious consequences. Points for attention are as follows:
1, fire hydrant system general bottom static pressure not more than 8kg, dynamic pressure 5kg.
2, at the most unfavorable pressure test fire hydrant, the pressure is not less than 0.7kg, water column can reach 7 meters.
3, the old engineering fire hydrant system test, pay attention to the pump flow and lift, generally more than two water nozzles, otherwise it may cause excessive pipe pressure.
4, test hydrant button should pay attention to whether the f
您可能关注的文档
- 燃气管网地理信息系统(Gas pipeline geographic information system).doc
- 燃气锅炉安全保护装置故障分析(Failure analysis of gas boiler safety protection device).doc
- 燃气涡轮发电机的基础知识(Basic knowledge of gas turbine generators).doc
- 燃气灶常见故障及处理方法(Common troubles and treatment methods of gas range).doc
- 燃气灶具常见故障及解决方法小常识(Common faults and solving methods of gas cooker).doc
- 燃烧器(burner).doc
- 燃油税(Fuel tax).doc
- 燃油压力压力(Fuel pressure pressure).doc
- 深圳晶石电器(Shenzhen crystal electrical equipment).doc
- 深圳全部工业区(Shenzhen all industrial zone).doc
最近下载
- 信阳农林学院《公共英语一》2023-2024学年第一学期期末试卷.doc VIP
- 个人征信报告模板征信报告模板(2021带水印).pdf VIP
- 如何做好医患沟通(1)(1).pptx VIP
- 4.4天净沙秋思 教学课件(共29张PPT)(含音频+视频).pptx VIP
- 毕业设计(论文)-基于PLC智能分类垃圾桶设计.docx VIP
- 消防给水管道水压试验方案.docx VIP
- 标准图集-闽2004G104 钢筋混凝土桩基承台.pdf VIP
- 江苏西德电梯图纸一体机KFS25-Y4F-B110(有机房).pdf VIP
- 《桉树更新免炼山造林技术规程》.docx VIP
- 免炼山造林PPT课件.pptx VIP
原创力文档


文档评论(0)