结构布置(The structure arrangement).docVIP

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
结构布置(The structure arrangement) The structure arrangement Classification: architectural design | label: architectural design Structural design specification Mainly is the design basis, the seismic grade and level of civil air defense, to love and the bearing capacity of gay, moistureproof, live load value, material level, the matters of attention in the construction, choose detail, detail drawing or nodes, and did not draw in the shop drawing and through instructions to convey information. For example, cement mortar shall be used as below zero, and mixed mortar shall be used. And so on. 2. Structure layout of each layer, including: (1) layout of precast board (selection of plates, size of plates and reinforcement). When marking the number and type of precast plate, do not use diagonal form. Because this method is easy to cross the line, use horizontal or vertical lines, the same type of room direct standard room type number. Should complete building unified number, can reduce design workload, also facilitate construction personnel to look at the picture. The seam is as high as 40, which can not be reinforced or reinforced. When cloth board, from inside the room to cloth board, use wide board as far as possible, the current casting belt is left in the window, the current cast bandwidth is better than 200 (consider the vertical tube of water warm). The seam should be more than 60 if the structure requires an entire cast. The whole layer is 50, with two - way phi 6 @ 250, concrete C20. The horizontal wall or transverse wall (horizontal wall) shall be used to combine the load-bearing scheme with good resistance to collapse. No precast board is allowed in the constructional column. It is suggested that the PMCAD should be used for the precast board of the worksheet, which may not meet the requirements of the users construction drawing and can only meet the requirements of defining load transmission line. It is very sensitive to the floor height, over 6.9 meters, or if it

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档