消防安装常见问题(Common problems with fire protection installation) Fire automatic fire extinguishing system 1. The system wiring is not reasonable, such as the line color is not unified, the line is not strong, the school line is not recorded, the terminal row is not standard, the wiring error, the concealed engineering tube protection is not in place. The line of fire line and alarm is worn in the same line, the weak current and the power line are laid in the same bridge or wire groove. 2, some engineering insulation resistance of less than 20 M Ω, the individual is only 0.5 M Ω, thus affecting the reliability of the system is running. Work grounding and protective grounding is not done, and there is no grounding resistance test record. The power connection of the alarm controller is connected to the plug. Alarm control cabinet inner wire not numbered, unbound. 3. The installation of fire detector is not strong enough. The location of the outlet and beam is too close. The detector confirms that the direction of the lamp is incorrect. Manual alarm button installation height does not meet the specification requirement. The mounting position of the display panel (floor indicator) is higher. Hydrant system 1. The float valve of the fire pool is not installed. 2. Valve in the suction hose of fire pump adopts butterfly valve, which adopts concentric diameter. No pressure gauge, water discharge valve, pressure relief valve outlet pipe. 3. The one-way valve on the outlet pipe of fire water tank is installed on the riser, and the fire water tank has no water level indicator 4, fire pump adapter is apart from the outdoor fire hydrant or pools of water inlet, far not located in the roadside, installed under the glass curtain wall, the installing height is not zero, the system, did not belong to the direction of the check valve is not correct, repair valve in a normally open state. Of 5, pipe diameter DN 100 or less welding, pipe anti sway bracket, outdoor pipe did not have heat pres

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档