电力系统自动装置简答(The power system automatic device short answer).doc

电力系统自动装置简答(The power system automatic device short answer).doc

  1. 1、本文档共24页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
电力系统自动装置简答(The power system automatic device short answer) 1, parallel operation: random variation in the power system load, in order to guarantee the power quality, and meet the requirements of safety and economic operation, often will stop and run operation of generator, put a stay in no-load generator after the necessary adjustment in the system, under the condition of satisfy in the switch and the system operation, the operation process is called parallel operation. 2, penecontemporaneous juxtaposition: stay and generator excitation, first to make the generator set up voltage, adjust the voltage and frequency of the generator, with the system voltage and frequency is close to equal, choose the right time to make the generator voltage and system voltage on the phase Angle difference is close to 0 o close tied for circuit breaker, the generator power grid. 3, the same period since the juxtaposition: approach without excitation, synchronous speed generator into system, then to the generator and excitation, in the original regulated torque and synchronous torque under the action of the generators into synchronization, complete with operation. 4. Juxtaposition of the same time point: the condition of generator power grid connection. The parallel points of the same period are the same, the same power frequency and the same voltage. 5. Slip difference, slip frequency and slip cycle: slip difference: the difference between the voltage and electric angular velocity of the generator on both sides of the circuit breaker and the voltage of the system; Slip cycle: the parallel circuit breakers on either side of the generator voltage and system voltage phase Angle difference between the time required for 360 °. 6. Constant off-line phase Angle is juxtaposed: the constant Angle of the front phase Angle of the two phases of Ug and Ux is called constant, and the parallel device is called constant. The whole step voltage, sinusoidal whole step voltage, linear full step voltage: a

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档