网站大量收购独家精品文档,联系QQ:2885784924

非常详细的建筑工程钢筋绑扎隐蔽验收内容(Very detailed construction of steel banding concealed acceptance content).doc

非常详细的建筑工程钢筋绑扎隐蔽验收内容(Very detailed construction of steel banding concealed acceptance content).doc

  1. 1、本文档共8页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
非常详细的建筑工程钢筋绑扎隐蔽验收内容(Very detailed construction of steel banding concealed acceptance content) Very detailed construction rebar hidden acceptance.Txt The following is a very detailed construction rebar hidden acceptance, there is a very strong direct role in practical work: The 1 column content: The 1.1 column root reinforcement cement slurry has been cleaned. 1.2 in order to ensure the column main reinforcement position is accurate, the distance control box The 1.3 column rebar: The number of 1.3.1 stirrups are determined according to the requirements of the drawings, the first distance 50mm is arranged at both ends of stirrups. 1.3.2 in the vertical reinforcement stirrup painting line of position from the top down, and then by entwisting binding method. 1.3.3 joint stirrups shall be staggered along pillar reinforcement lashing, stirrups and vertical ribs to be vertical, tied to buckle wire head. 1.3.4 dark stirrups and wall reinforcement lashing requirements: dark stirrups and wall horizontal reinforcement shall be staggered over 20mm and together. 2. wall, column, beam reinforced dark: The 2.1 wall root steel cement slurry has been cleaned. 2.2 wall reinforcement has been adjusted. The displacement is too large to adjust according to the requirements of 1:6, a steel hook will move, not vertical straightening. 2.3 initial design requirement: 2.3.1 dark side the first column root wall reinforcement column distance of 50mm. 2.3.2 first wall reinforced concrete wall surface distance 50mm. The first column 2.3.3 stirrups distance concrete 30mm. 2.3.4 continuous beam from the dark side of the stirrup column started 50mm. 2.3.5 as a continuous beam stirrup column stirrups 50mm. The 2.4 wall vertical reinforcement requirements: 2.4.1 lap length not less than 45d, the joint guarantee has three horizontal bars. Binding range of not less than three. Wall stud 50% staggered, the staggered distance of not less than 1.3 times in the adjacent joint - lap length. 2.4.2 wall horiz

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档