高层建筑暖通空调设计中存在的问题及解决办法(Problems and solutions in HVAC design of high-rise building) First, carry out the implementation of design specifications and standards of the actual problems and Solutions 1 ventilation and air conditioning system of fire valve setting does not conform to the standard The provisions of the high regulation, the wind pipe can not pass through the firewall or deformation cracks, such as must pass through, should be set in the fire valve through the firewall; through the deformation joints, should be set on both sides of the fire valve. However, some high-rise buildings, the wind pipe wear firewall did not set fire damper, is only provided with a fire valve in the side duct through some deformation joints, while the other side is not set. 2 air conditioning pipeline laying slope does not meet the specification requirements Design standard provisions, laying of air conditioning pipeline should have a certain slope, the slope water should be 0.003, not less than 0.002. However, some air conditioning engineering for backwater slope is only 0.001 ~ 0.0015. Some projects because of conditions, the slope can not reach this requirement, can increase the riser to solve them in the proper position. 3 determine the anti smoke staircase compartment airflow has a problem Smoke staircase compartment of pressurized air supply provisions against high regulation of the high-rise building, and given specific volume value. The article notes that when open the door through the door of the wind should not be less than 0.7 m/s; provisions in the provisions of the number of open doors, 20 floors below 2, 20 floors above 3. High regulation also stipulates that the smoke proof staircase room outlet should be a set of each layer. According to these regulations, we can calculate the outlet air layer room should be L/2 (20 floors below) or L/3 (more than 20 layers, L total pressurized air supply). However, some engineering, the stairwell anteroom outlet air was labeled as L

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档