Non linear static analysis of masonry structures ...(砌体结构的非线性静态分析)
Non linear static analysis of masonry structures
Simplified equivalent frames and accurate models
R. Sabatino G. Rizzano
Department of Civil Engineering, University of Salerno
Via Ponte Don Melillo, 84084 Fisciano (SA) - Italy
ABSTRACT
The achievement of performance-based earthquake engineering for the seismic assessment of buildings has lead
to the application of a number of non-linear static procedures. Different strategies of modelling have been
adopted for masonry structures; nevertheless, due to the complex non-linear behaviour of masonry panels, the
choice of the appropriate model is a matter of paramount importance, as many aspects must be taken into
account in order to achieve a balance among the complexity of the model itself, the computational effort and the
accuracy of the obtained results.
Within this framework, the equivalent frame model, despite its strong simplifications, can be considered as an
effective way to predict the structural response of masonry structures, provided that the main issues of this
method are carefully investigated.
This paper deals with the elaboration of the software FREMA, purposely developed by the authors, aimed at
predicting the force-displacement curves of masonry walls subject to in-plane forces, modelled by means of
equivalent frames. The computer program herein proposed has been validated by means of a comparison with
experimental and numerical results available in literature.
Keywords: Masonry walls, Finite Elements, Equivalent Frames, Non-linear static analyses, Pushover Curve
1. INTRODUCTION
The adoption of performance-based earthquake engineering concepts has lead to the application of a
number of non-linear static procedures in the seismic assessment of buildings - the coefficient method
(ASCE, 2000), the capacity spectrum method (ATC, 1996; Freeman, 1998), the N2 meth
您可能关注的文档
- MSeals Co., Ltd.(MSeals有限公司。).pdf
- MUD PUMP GASKETS VALVE CAP GASKETS (泥浆泵垫圈阀盖垫片).pdf
- MTAOM Original Magnetic Drive Pumps(MTAOM 原始磁驱动泵).pdf
- Mud Valves Pressure Floor Boxes Trumbull MFG(贝瑟尔泥浆阀压力层框特兰伯尔制造).pdf
- MULTI PULL POLY V BELTS India Limited(多聚 V带拉印度有限).PDF
- MULTIDIAMETER, BIDIRECTIONAL PIGGING (MULTIDIAMETER,双向清管).pdf
- MultiLeaf Spring and Hotchkiss Suspension CAE (多叶春天和霍奇悬挂CAE).pdf
- MULTIDIAMETER PIGGING – FACTORS (MULTIDIAMETER清管因素).pdf
- MuffinsMuffins! Muffins(MuffinsMuffins !).pdf
- Multipath Fading Channel Modeling and (多径衰落信道建模和).pdf
文档评论(0)