基于多agent技术的站域保护系统的研究 research on substation-area protection system based on multi-agent system.pdfVIP

基于多agent技术的站域保护系统的研究 research on substation-area protection system based on multi-agent system.pdf

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
基于多agent技术的站域保护系统的研究 research on substation-area protection system based on multi-agent system

第 41 卷 第 3 期 电力系统保护与控制 Vol.41 No.3 2013 年 2 月 1 日 Power System Protection and Control Feb.1, 2013 基于多Agent技术的站域保护系统的研究 王 媛,焦彦军 (华北电力大学电力系统保护与动态安全监控教育部重点实验室,河北 保定 071003) 摘要:针对传统变电站基于元件信息的后备保护动作时限和定值配合繁杂的弊端,提出基于本地信息的站域保护。该保护由 电流元件和电压元件构成,原理简单可靠,在主保护及断路器拒动时具有后备保护和断路器失灵保护的功能,同时近后备和 远后备的动作时限相同,能够快速切除故障。并提出基于多Agent技术的站域保护系统,运行方式改变时该系统能够自适应 地调整保护定值,提高了保护灵敏度。 关键词:110 kV终端变电站;站域保护;后备保护;断路器失灵保护;多Agent技术 Research on substation-area protection system based on multi-Agent system WANG Yuan, JIAO Yan-jun (Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education, North China Electric Power University, Baoding 071003, China) Abstract: Traditional backup protection in substation is based on component information, and cooperation of movement time limit and fixed value is complicated. Based on substation area information, the substation area protection scheme is presented. Its principle is simple and reliable based on current component and voltage component. It functions as backup and breaker failure protection when main protection or breaker fails and can clear faults quickly as its remote backup and short-range backup have the same time limit. The substation area protection system based on multi-agent system is presented. The system can regulate fixed value adaptively to improve sensitivity of protection when substation operation mode changes. Key words: 110 kV terminal substation; substation area protection; backup protection; breaker failure protection; multi-agent system 中图分类号: TM772 文献标识码:A 文章编号: 1674-3415(2013)03-0080-06 部利用互联信息或是通过保护间的相互配合提高保 0 引言 护性能,并没有脱离传统的元件保护的思想。

您可能关注的文档

文档评论(0)

hello118 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档