(MTT498—1995) CKJ系列交流真空接触器维修检验技术规范((MTT498-1995) CKJ series ac vacuum contactor maintenance test technical specification).doc

(MTT498—1995) CKJ系列交流真空接触器维修检验技术规范((MTT498-1995) CKJ series ac vacuum contactor maintenance test technical specification).doc

  1. 1、本文档共17页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
(MTT498—1995) CKJ系列交流真空接触器维修检验技术规范((MTT498-1995) CKJ series ac vacuum contactor maintenance test technical specification)

(MTT498—1995) CKJ系列交流真空接触器维修检验技术规范((MTT498-1995) CKJ series ac vacuum contactor maintenance test technical specification) (MTT498-1995) CKJ series ac vacuum contactor maintenance test technical specification. TXT falls, and then cries ~ ~ ~ ~ ~! Thats the best way to show off!! Dont eat full which have the strength to lose weight? Im sorry to make you laugh. I can resist everything except temptation... Lao zi not only has a car, but also his own... (MT/T498-1995) CKJ series ac vacuum contactor maintenance test technical specification 1. Subject content and scope of application This standard provides for the technical requirements, test methods and inspection rules for the use of a series ac vacuum contactor for CKJ series. This standard applies to the use of the CKJ series ac vacuum contactor (hereinafter referred to as contactor) This standard does not apply to the product identification inspection, factory inspection, type inspection and arrival and acceptance of the contactor. Other serial contactor maintenance tests can also be used. 2. Reference standards GB 1497 basic standard for low voltage electrical appliances Basic test method of GB 998 low voltage appliances 3. Technical requirements 3.1 performance requirements 3.1.1 dielectric performance 3.1.1.1 working frequency withstand pressure: The main circuit, control circuit and auxiliary circuit of the contactor shall be in accordance with table 1. 3.1.1.2 insulation resistance: The main circuit and auxiliary circuit insulation resistance of the contactor should not be less than table 2. 3.1.2 action performance 3.1.2.1 when the rated control power voltage is 75 % ~ 110%, the contactor should be able to absorb reliably; When the control power voltage is reduced to 60% U, the contactless contactor should not be released; In the case of contact wear, the minimum release voltage of the contactor should not be less than 20% of the communication (at the rated frequency), and the dc is not less than 10% of Us. The

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档