配电变压器常见故障分析(Analysis of common faults in distribution transformers).doc

配电变压器常见故障分析(Analysis of common faults in distribution transformers).doc

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
配电变压器常见故障分析(Analysis of common faults in distribution transformers)

配电变压器常见故障分析(Analysis of common faults in distribution transformers) Distribution transformer common fault analysis return list 1 abnormal sound (1) when the sound is large and noisy, it may be the problem of the transformer core. For example, when clamping or compressing the screws of the iron core is loose, the instructions of the instrument are normally normal, and the color, temperature and oil level of the insulating oil are not changed greatly, and the operation of the transformer should be stopped and checked. (2) the boiling sound of water in the stereo sounds, and the sound of bubbles escaping out of the sound may be caused by serious faults in the winding, so that the parts near them are seriously heated and gasified. The contact of the tap changer is bad, and the local point is seriously overheated or the transformer turn to turn short. At this point, the transformer should be stopped immediately for maintenance. (3) when there is an explosion in the sound, it is possible that the insulation of the transformer is breakdown when it is large and uneven. At this time, the transformer should be stopped running, maintenance. (4) when the sound of discharge is heard in the audio, it is possible that the transformer body or casing has partial discharge on the surface. If it is a problem of sleeve, in bad weather or at night, can also see the corona or glow blue, purple spark, at this time, should clean up the casing surface dirt, and then coated with silicone or silicone coating. At this point, stop the transformer and check the distance between the grounding of the iron core and the charged parts to the ground. (5) audio clip has a regular impact or friction sound may be continuous, when certain parts of the transformer core vibration caused by mechanical contact, or because of abnormal noise caused by electrostatic discharge, and a variety of measuring meter indication and temperature have no reaction. This kind of noise while abnormal, but no harm on the run,

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档