pkpm结构设计参数(PKPM structural design parameters)
pkpm结构设计参数(PKPM structural design parameters)
PKPM structural design parameters 1 (response call, direct out)
PKPM structural design parameters
Paper upload: zhen9280 message Author: God Xia, you are the 29155th reader of this article
Abstract: This paper introduces the PKPM software TAT, SATWE and PMSAP changes between the old and the new version of the specification, which is also the new and old standards (provisions norms, rules, change of seismic load, high-rise concrete standard specification.
Keywords: PKPM design calculation
--------------------------------------------------------------------------------
1. wind load
The formula of the standard value of wind pressure is WK=, Z, W, s, Z. Of which: z=1+ beta zeta phi z/ V Z in the new standard, the basic pressure Wo increased slightly, and the construction of the wind pressure height coefficient E, fluctuating amplifying coefficient, fluctuation influence coefficient are the decrease of V. Therefore, the standard value of wind pressure calculated according to the new specification may be larger than the 89 standard and may be smaller than the 89 standard. The specific changes include the following:
1), the basic wind pressure: new load specification will return period wind load basic value from 30 years to 50 years: the provisions of article 3.2.2 of new rules: for high-rise buildings B height or especially important high-rise buildings, should be according to the wind pressure in 100 years by value.
2) ground roughness class: from the original A, B, C class, changed to A, B, C, D class. The C class refers to the urban areas with dense buildings; the D class is a densely built-up urban area with higher housing.
3) the change coefficient of the height of the Phoenix pressure: A, B, C, the corresponding wind pressure height change coefficient is slightly adjusted. The coefficient of variation of the wind pressure height corresponding to the newly increased D class is 20% to 50% smaller than the C class.
4) the p
您可能关注的文档
- dnf异常状态(DNF abnormal state).doc
- dcl-4计算书(Dcl-4 statement).doc
- dns与断网(DNS and off the net).doc
- dns问题(DNS problem).doc
- document对象(文件对象).doc
- dnf蓝拳技术讲解(Explain the DNF blue boxing technique).doc
- dom4j通过xpath查询xml(Dom4j query XML by XPath).doc
- dom对象常用方法(DOM objects commonly used methods).doc
- dom解析xml文档(DOM parsing XML documents).doc
- dos下各种常见命令索引(DOS under the common command index).doc
文档评论(0)