网站大量收购独家精品文档,联系QQ:2885784924

plc常见故障的逻辑示意图的实现方法(PLC common fault logic schematic diagram method).doc

plc常见故障的逻辑示意图的实现方法(PLC common fault logic schematic diagram method).doc

  1. 1、本文档共8页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
plc常见故障的逻辑示意图的实现方法(PLC common fault logic schematic diagram method)

plc常见故障的逻辑示意图的实现方法(PLC common fault logic schematic diagram method) Realization method of logic diagram for common faults of PLC 1 Preface In the various control systems composed of PLC, Because of the complicated logic relations, various control components, distributed actuators and equipment operation, once the failure will occur misoperation or external components and equipment caused by the loss of production and safety accident. Then, in the design of the control system, we must take full account of this, in order to facilitate maintenance and maintenance of the premise, automatic, timely and accurate diagnosis and display of all kinds of fault information is particularly important. This paper gives the logical diagram and schematic diagram of the common fault diagnosis, and explores a practical way to display, alarm and archive the information. 2 PLC system fault type PLC system failures can be as follows: 2.1 state conflict diagnosis Infrared, according to the signal between the device and components, to check whether their actual state is in logical contradiction, and if so, there must be one of the signals as false state. For example, an upper and lower sliding cylinder, the upper and lower proximity switches, such as the same type, and often open in the same circumstances, such as the two close to the switch signal, as 1 When one of the switches fails, a fault message is generated. Use logical diagrams to indicate the following: In Figure 1, I 1 and I 1.1 represent upper and lower limits, respectively. When I 1 acts, I 1.1 acts, PLC is diagnosed as fault M . Similar to the motors forward and reverse signals, the switch normally open and normally closed signal can not occur simultaneously. 2.2 action interlock condition fault In order to ensure the normal operation of a specific device or the correct operation of the executing agency, it is necessary to provide the interlocking conditions of the action, such as the safety switch, the readiness of the equipm

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档