准确确定框架—剪力墙结构中各分部结构的抗震等级(To accurately determine the seismic level of each segment structure in frame shear wall structure of the).doc

准确确定框架—剪力墙结构中各分部结构的抗震等级(To accurately determine the seismic level of each segment structure in frame shear wall structure of the).doc

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
准确确定框架—剪力墙结构中各分部结构的抗震等级(To accurately determine the seismic level of each segment structure in frame shear wall structure of the)

准确确定框架—剪力墙结构中各分部结构的抗震等级(To accurately determine the seismic level of each segment structure in frame shear wall structure of the) Frame shear wall structure is a kind of common structural form of building engineering. In the frame shear wall structure, the ratio of the seismic overturning moment and the total overturning moment of the structure is the important basis to determine the seismic grade of the frame and shear wall. In this regard, GB50011-2001 code for seismic design of buildings 6.1.3 JGJ3-2002 , technical specification for concrete structures of tall building 8.1.3 made clear, how to understand the code spirit, accurately determine the seismic grade frame, shear wall, ensure the design quality of the reinforced concrete frame shear wall structure, structure designers often encounter problems. Let me talk about some of my personal knowledge. The GB50011-2001 specification 6.1.3 stipulates: the frame shear wall structure, the basic mode of action, if part of the frame under seismic overturning moment is greater than the total seismic overturning moment of the 50%, the seismic grade frame portion shall be determined according to the frame structure, the maximum height is appropriate to increase the frame structure. The JGJ3-2002 specification 8.1.3 stipulates: the frame shear wall structure seismic design, earthquake effect in basic mode, part of the framework under seismic overturning moment is greater than the total seismic overturning moment of the 50%, the seismic grade should be part of the framework by the use of the framework structure; the maximum height and width of the comparable framework appropriate increase. The spirit of the provisions of the two is consistent. According to the above provisions, the shear wall structure design of reinforced concrete frame, first of all should be based on the percentage of frames under seismic overturning moment total seismic overturning moment, to determine their level of seismic frame shear wall. Usually, ac

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档