摘要: 对旋流燃烧器前墙布置与前后墙对冲布置方式锅炉的空气动力特性、水动力特
性、汽温特性等进行比较,分析两种布置方式的优劣,在锅炉设计、运行中采取有效措施,保
证锅炉安全、经济运行。
关键词:旋流燃烧器;前墙布置;前后墙对冲布置;特性对比
中图分类号:TM621.2文献标识码: B
ThetraitcoIltrastand of burI地rwithf}ont、砌lcolIocation
analysisrotary
andf}ont&backwaUcrosscoIlocatiOnforboner
LIU
Cheng
ElectricPowerScientific Institute,Yinchuan
(Ningxia TbchnologyEngineering750D02China)
Abstract: t}lech眦cteristicofair arIdsteam of
Compares dyn锄ics,hydrodynamicstemperatm.e
widlfrontwallcollocationaJldfrontandbackwallcrosscollocation
forboiler,
rot£町bumer analyzes
afld oftwo ofcollocationsoe仃ectiVemeasuresc蛐betal【enin
adV肌tagedisadVantagetype modes,
boiler and tlleboilersafeandeconomical
designoperation,guarantees operation.
waU andbackwaUcross contr踮t
wo“b:rotarybumer,fbntcoUocation,f南nt coUocation,trait
Key
1 前言
旋流燃烧器常用的布置方式主要有:前墙布 共24只双通道轴向旋流燃烧器。正常运行时3层
置、前后墙对冲或交错布置,此外,还有丽侧墙对 投运,1层备用。
冲或交错布置和炉顶布置等,其中,前墙布置和前 宁夏大坝电厂4×300Mw机组锅炉是由中外
后墙对冲或交错布置在我国应用较为广泛。 合资北京巴威公司引进美国技术制造的型号为
国电石嘴山4×330Mw机组锅炉是由武汉锅
炉厂设计制造的型号为wGl004,18.4—2亚临界中包炉。该炉燃烧器采用前后墙对冲布置,制粉系统
间一次再热自然循环汽包炉。该炉燃烧器为典型 采用正压直吹式,每台锅炉配有5台MPS—190型
的前墙布置,制粉系统采用正压直吹式,每台锅炉 中速磨煤机,对应锅炉前后墙布置5层(前墙3
收稿日期:2005-02—25
作者简介:刘成(1977一),男,工程师,从事锅炉试验研究工作。
您可能关注的文档
- 蓄电池组与高频逆变器阻抗匹配特性研究 study of impedance matching characteristics of accumulator packs and high frequency inverter.pdf
- 蓄能电厂静止变频启动装置启动失败问题研究 starting failure of static frequency converter for pumped-storage power stations.pdf
- 蓄冷技术在石家庄市制药行业中的应用 the application of cool storage systems in shijiazhuang pharmaceutical industries.pdf
- 蓄冷空调用电技术在北京地区的应用 application of ice cooling storage air-conditioning technique in beijing area.pdf
- 蓄电池组恒流放电系统建模及闭环仿真 accumulator battery constant-current discharging system modeling and its simulation.pdf
- 蓄冷空调项目电力移峰填谷效果评价及现场测试 evaluation and spot test of peak load shifting ability for cold storage regenerator system.pdf
- 蓄能器在解决汽动给水泵跳闸问题中的应用.pdf
- 蓄热电锅炉技术应用分析 application analysis on electric boiler with thermal technology.pdf
- 蓄热电锅炉技术及其移峰填谷效果的评价方法 electric heat-storage boiler technology and the evaluation method of its peak load shifting effect.pdf
- 蓄水屋面在西安市的应用分析 analysis of the feasibility of the water-stored roof in xi'an.pdf
最近下载
- 2024年青海省中考语文试卷.doc VIP
- MLflow:MLflow模型版本控制教程.docx
- 症状严重程度每日记录量表的引进及信效度检验.doc VIP
- 英语专业四级考试阅读分析.ppt VIP
- 2025年拍卖师绿色拍卖与可持续发展理念在企业中的推行专题试卷及解析.pdf VIP
- 2025年金融风险管理师环境衍生品与碳交易市场专题试卷及解析.pdf VIP
- 面向文化遗产保护的AI伦理治理框架.pdf VIP
- 人教版高中化学选择性必修3全册教学课件.pptx
- 2025年信息系统安全专家物理渗透测试技术专题试卷及解析.pdf VIP
- 埃及风荷载设计规范EGYPT_Chapter-7-Wind-Loads-Egyptian-Load-Code.pdf VIP
原创力文档

文档评论(0)