锚索施工方法(Anchor cable construction method)
锚索施工方法(Anchor cable construction method)
1] TB10001-99 code for design of railway subgrade [S].
[2] TBJ202-2000, construction standard of railway subgrade [S].
Li Minghua, Xu Shaoping. Construction technique of retaining wall, slope protection and anchor cable combined support for cutting slope. [J]., railway standard design, 2003 (1). 3
4 Zhang Zijun, Lei Weidong. Cutting slope anchor construction technology of [J]. railway standard design, 2003 (Supplement).
Liang, Liang, Xia Xiong. Finite element simulation and stability evaluation of slope strengthened with prestressed anchor cable [J]. standard of railway design, 2003 (12). (5)
Chu 6, Shen Wu. Application of prestressed anchor pile technology in landslide regulation [J]. design of railway standards, 2003 (3)
For highway subgrade engineering excavation, large quantity, high cutting slope, poor geological sections generally adopts prestressed anchor cable beam, in order to ensure the stability of high slope subgrade. Prestressed anchor cable beam construction is a complex geological conditions, engineering and construction of key concealment technology difficult to arrange special construction work, a trained professional construction team, has rich experience in the construction of the construction. The main construction procedures are as follows:
1 、 anchor hole measurement
Side slope construction, side reinforcement, that is, excavation level, protection level, shall not be excavated at the end. According to the site engineering elevation, according to the design requirements, the position of anchor hole accurately on the slope, hole position error not exceed 50mm. In case the existing brush side slope surface is not smooth or difficult, it needs to be approved by the design supervision unit. Under the premise of ensuring the stability of the slope and the safety of the structure, the positioning accuracy should be relaxed or the location of the anchor hole should be adjusted.
2 drilling equipment
The selectio