2014中级电工试卷不得外传带答案的(2014 intermediate electrical examination papers shall not be accompanied by answers).docVIP

2014中级电工试卷不得外传带答案的(2014 intermediate electrical examination papers shall not be accompanied by answers).doc

  1. 1、本文档共9页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
2014中级电工试卷不得外传带答案的(2014 intermediate electrical examination papers shall not be accompanied by answers)

2014中级电工试卷不得外传带答案的(2014 intermediate electrical examination papers shall not be accompanied by answers) Grade 2014 electrician skill test (intermediate worker) Total score: 100 minutes, time: 90 minutes Type 1 (26 points), two (14 points), three (22 points), four (26 points), five (12 points) total score Score Fill in the blanks (0.5 cents per room, 26 points) 1, in order to prevent personal indirect electric shock damage and leakage protection appliances, TN system should be installed in the (distribution line at the end); and TT system can be installed in (low voltage power line). 2, IP55 meaning: front 5 means dustproof, after 1 5 said (water spray harm). 3, 800KVA high voltage current transformer (46.19A), low voltage current (1154A), short circuit current (19KA), selection of high voltage fuse current formula (0.6Ie), selected for low voltage fuse current formula for the low voltage (2Ie), copper (1*80*8) standard single-phase busbar. 4, known for three-phase motor capacity, the rated current formula: 220V (1Kw3.5) A, 380V (1Kw2) A 5, 1600Kva distribution transformers have 11Kw4 not frequent motor starts matching model for air (CM3-100M/32002, 25~32A) (CK3 25~30) with A (JR3 18~25) with contactor, thermal relay A, cable type (VV4*4), with protective tube diameter (25). 6, LZZBJ9-10A 0.2/0.5/10P/20 means: L: current transformer, Z: (pillar) Z: (pouring) B: (with protection level) J: (enhanced) 9: design serial number 10: rated voltage (kV), A: the structure of the code, 0.2: (0.2 0.5: (0.5 level measuring winding) measuring winding) 10P20: (composite error less than 10% of the windings of the 10P protection level of a flow 20 times.). 7, Icw: bus under the specified test conditions, (safety bearing second current RMS) Ipk: bus under specified test conditions (capable of safely carrying peak current Ipk=2.2 Icw) 8. The thermal stability factor is the ratio of current in a thermally stable current 1s that does not cause current transformers to exceed the permissib

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档