建筑设计中常犯的错误!!(A common mistake in architectural design!!)
建筑设计中常犯的错误!!(A common mistake in architectural design!!)
Between the 1. fire elevator room and other room partition door hole without a fire doors.
2. at the entrance to the underground garage fire wall without a fire doors, and air door instead of first class fire door. (Z i still do not know)
3. underground garage access door is not closed staircases set B fire doors.
The 4. car ramp at the entrance did not set fire shutter.
A spray system 5. in the basement after a fire partition area is still more than 1000 square meters. (non real garage)
6. underground garage to fire district area more than 500 square meters
Between the 7. diesel generator room and oil storage room without a fire doors, and did not take measures to prevent oil flow.
(the above reason is the specification specified by the provisions of the contents of a, B and C fire door is not familiar with)
8. equipment door should not directly open to the staircase.
9. fire door opening direction toward the deformation joint.
10. staircase elevator combined atria window opening area less than 3 square meters, does not meet the high.
11. double staircase and public stair guardrail used cross railing; teaching platform, staircase, balcony, low window
Choose the form of easy to climb the railing, does not meet the specification requirements.
12. the special building standard provisions are not familiar with the design, the implementation is not in place (such as sports construction etc.).
13. bedroom, kitchen upper toilet, did not take waterproof, sound insulation and easy maintenance measures.
14. glass covers more than 1.5 square meters, in that the safety glass doors and windows.
15. above the kitchen window opening should be set fire canopy not less than 1M, should meet the norms design catering building JGJ64-89 section 3.3.11. (restaurant)
17. staircase width refers to the outer wall to the center armrest width, the top is not less than 1200mm.
18. high-rise building evacuation door to ensure the width o
您可能关注的文档
- 通过信给银行合作.pdf
- 遗产解释制度.ppt
- 郑州商城布局与外墙趋势新探索.pdf
- 那么问题也是最受欢迎热门答案.pdf
- 酸雨对作物影响.ppt
- 遵守法律.doc
- 重庆47剧院.doc
- 配方软件BESTMIX.pdf
- 通用名ppt.ppt
- 重庆当地导游基础知识.doc
- 建筑论文发展私营建筑经济的思考(Architectural papers Reflections on the development of private construction economy).doc
- 建筑设计规范常识(Common sense in architectural design).doc
- 建筑设计基础(Architectural design basis).doc
- 建筑设计与专利(Architectural design and patent).doc
- 建筑识图(Architectural drawing).doc
- 建筑设计中存在的问题(Problems in architectural design).doc
- 建筑防火疏散(Building fire evacuation).doc
- 建筑面积算法(Building area algorithm).doc
- 建筑面积计算规则2006(Building area calculation rule 2006).doc
- 建筑预算知识(Building budget knowledge).doc
文档评论(0)