志高空调故障(Chigo Air Conditioner Fault).docVIP

志高空调故障(Chigo Air Conditioner Fault).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
志高空调故障(Chigo Air Conditioner Fault)

志高空调故障(Chigo Air Conditioner Fault) 285, 325, 388, Chigo Air Conditioner fault code table 418: Including: 03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 13, 35, 40, 41 The contents of trouble running lights LED1 Running lights timing lights The indoor coil temperature sensor fault /8 1 seconds light shining The indoor temperature sensor fault /8 2 seconds light shining The outdoor unit fault 5 /8 seconds light shining The indoor fan fault 6 /8 second light shining 1, flashing a bright 0.5 seconds, 0.5 seconds off. 2, standby state detection, display the indoor coil sensor fault, the indoor temperature sensor fault. 3, if the indoor fan operation, for 30 seconds without feedback signal, turn off air conditioning and indoor fan fault display. In two, high crystal color series air conditioner fault code: Including: 02, 16, 18, 19, 20 The contents of the digital display shows fault code The indoor temperature sensor fault L2 switch state display, if at the same time show the fault code L1, repair immediately after the back room The indoor coil temperature sensor fault L1 The indoor fan fault L6 indoor fan operation, for 30 seconds without feedback signal is shut off and display L6 The outdoor unit fault E5 shutdown after E5 set temperature effectively, but no digital tube display, emergency or remote open / close button cough reboot, digital tube display at room temperature Three, the day series, a series of hook (51 and 51) models of fault code Including 25, 26, 42, 43, 45, 46, 47, 48, 50, 51, 52 The content of digital tube display state fault The indoor coil sensor fault E3 The indoor temperature sensor fault E2 Abnormal E4 outdoor unit The indoor fan fault E5 Frost DF Four, 18NV/24NV (5100-6600W): Chigo Air Conditioning Including: 17, 34, 36, 37, paragraph Fault content running lights LED1 Room temperature sensor shining 2 /4 seconds off the display NO LCD fault content 1 E1 IPM module failure 2 E2 compressor current is too high 3 E3 high temperature compressor 4 E4 outdoor

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档