risk of pacemaker patients by taser x26 contact mode application泰瑟枪的起搏器患者风险x26接触模式应用程序.pdf

risk of pacemaker patients by taser x26 contact mode application泰瑟枪的起搏器患者风险x26接触模式应用程序.pdf

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
risk of pacemaker patients by taser x26 contact mode application泰瑟枪的起搏器患者风险x26接触模式应用程序

Journal of Electromagnetic Analysis and Applications, 2012, 4, 96-100 / 10.4236/jemaa.2012.42012 Published Online February 2012 (http://www.SciRP.org/journal/jemaa) Risk of Pacemaker Patients by TASER X26 Contact Mode * Application Norbert Leitgeb, Florian Niedermayr, Robert Neubauer, Gerhard Loos Institute of Health Care Engineering with European Notified Body of Medical Devices, Graz University of Technology, Graz, Austria. Email: norbert.leitgeb@tugraz.at Received December 22nd, 2011; revised January 20th, 2012; accepted January 29th, 2012 ABSTRACT The prevalence of pacemaker patients among the general population and of conducted energy devices (CED) for law enforcement and self-defence is increasing. Consequently, the question whether cardiac pacemaker (CPM) patients are on particular risk becomes increasingly important. The risk of Taser X26 electric interference with implanted CPM has been investigated by numerical simulation at MRI-based anatomical models of CPM patients with devices implanted at conventional sites (left pectoral, right pectoral and abdominal) and with the monopolar CPM electrode placed at the ventricular apex. In spite of 10 fold higher peak voltages the different coupling conditions make Taser-induced CPM interference voltages lower than those caused by external cardiac defibrillators. It is shown that electric interference considerably depends on ECD electrode orientation. The most unfavourable conditions are encountered with ECD elec- trodes aligned with the line from the CPM electrode tip to CPM can (EPC line). It could be shown that worst case inter- ference voltages of monopolar pacemakers of any kind of implantation remain below the pulse immunity level as de- fined in safety standards of implantable cardiac pacemakers and of cardioverter defibrillators. However, interference voltages exceed CPM sensing thresholds. Therefore, capturing should be expected at Ta

您可能关注的文档

文档评论(0)

xyz118 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档