网站大量收购独家精品文档,联系QQ:2885784924

春兰空调故障维修代码表(Code for fault maintenance of Chunlan air conditioner).doc

春兰空调故障维修代码表(Code for fault maintenance of Chunlan air conditioner).doc

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
春兰空调故障维修代码表(Code for fault maintenance of Chunlan air conditioner)

春兰空调故障维修代码表(Code for fault maintenance of Chunlan air conditioner) Code for fault maintenance of Chunlan air conditioner -------------------------------------------------------------------------------- Chunlan KFR-40, 50, 70, 100, 140LW/BdS Reasons of fault E1 fault display room inside and outside communication (voltage between GND and CMM swing around 6-7V) E2 compressor current E3 power supply voltage abnormal E4 refrigeration system high pressure protection, RT5 sensor abnormal E5 outdoor low temperature cold ring protection E6 protection (refrigeration state) E7RTI, RT2, RT3, RT2 abnormal temperature sensor open, E8RTI RT2, RT3 temperature sensor short Chunlan FR-180 and 260/S pipe mill Show the reason code E0 system fault voltage protection E1 two anti freeze protection E2 indoor temperature sensor open or short tube E3 indoor temperature sensor open circuit or short circuit E4 outdoor pipe temperature sensor open circuit or short circuit fault E6 E5 communication power supply protection E7 overcurrent protection E8 unloading protection E9 low voltage protection Chunlan RF-28W/AS10 air conditioning unit fault code Display power reasons of overvoltage and undervoltage fault lights three-phase power supply normal power over-voltage, flashing lamp power supply voltage is too low or too high (187-245V) abnormal defrost, lack of light air conditioning normal defrosting defrosting, phase light flash three-phase power phase (check signal line H and LP delay) overload, light air conditioning is three minutes delay delay, overload lights flash Heat protection K disconnect from voltage controller (check signal line B) Indoor signal wire terminal is defined as follows: A - B - power line voltage control and thermal protection input control line (weak ground), C - compressor output control line (weak ground), D outdoor pipe temperature sensor input connections (weak ground), E outdoor machine output control line (weak ground), F outdoor machine output control line (weak gr

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档