热敏电阻的长线测量抗干扰方法(Long term measurement anti-interference method for thermistor)

热敏电阻的长线测量抗干扰方法(Long term measurement anti-interference method for thermistor) The introduction of interference compensation circuit 1. The interference in the long term will cause oscillation, because your sampling is the current value, the interference can be equivalent to the current. 2. The R1 Series in the constant current source, the interference current through R1, the interference equivalent to the change of the constant current source is offset. 3. High frequency interference exists in the form of voltage measurement, and your speed is only 100Hz, easily filtered, as long as the detection circuit in a filter can. 4. It is recommended to use 4 line bridge connection (4 terminal resistance type), 3 wire connection in the strong interference environment may be a problem, because the 3 line method has an implicit assumption that the lead resistance bridge arm resistance, strong interference in the environment, long-term inductance tends to lead impedance into large multiplication. Youre not using the bridge You should not use the bridge is wrong, the first signal acquisition circuit you depend entirely on Yu Heng current source, a slight fluctuation will produce great error, in addition to being a good constant current source is also very easy. It is recommended that you may be the one on the bridge on the arm PT100. In addition, the problem of the hardware software can also be solved, for example, the temperature curve of PT is regular, we can design a compensation table on the ROM in the program design, according to the temperature measured by the look-up table for compensation value. In addition, you said that volatility is likely to be your constant current source caused by the fluctuation of. Thank you I did not use the bridge, mainly because of the bridge temperature Thank you I did not use the bridge, mainly because of the power supply to the temperature range of bridge and bridge have limited requirement. We are modifying the printed circuit board based

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档