GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101(乙二醇制冷系统故障诊断101).pdfVIP

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101(乙二醇制冷系统故障诊断101).pdf

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101(乙二醇制冷系统故障诊断101)

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you arrive to find high Fermenter temperatures and your glycol chiller system is not running. What is the first thing a brewer should do in this situation? Don’t panic and don’t jump to conclusions. There are several issues or conditions that can cause these alarms. Here we will cover the most common causes and the steps that you can do to remedy, diagnose, and even repair. The goal of this article is not to eliminate the services of a Refrigeration Service Technician, but perhaps minimize these calls to save both you and your service technician’s time. FREEZE, FLOW, OR LOW PRESSURE ALARM I can almost a guarantee, that sometime during the life of your chiller system you will experience a Freeze Alarm. These alarms can not only cause compressor and evaporator failures, but can also cause catastrophic system failures. For example; a ruptured evaporator can not only ruin your entire chiller system, but also contaminate your entire glycol piping loop with refrigerant and oil. Before we reset a Freeze Alarm, lets first see if we can determine what might have caused this alarm. 1) GLYCOL SOLUTION. Not only check the glycol percentage but also the level, or volume, of glycol in the storage tank. You want the freeze point of the solution to be 20-25 F below the thermostat set point- a safe rule of thumb is to operate with 1/3 Propylene Glycol to 2/3 Water mixture, providing a freeze point of approx. +5 F. The minimum storage tank glycol level varies by manufacturer. You must make sure that when all of the pumps are on,

您可能关注的文档

文档评论(0)

hhuiws1482 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:5024214302000003

1亿VIP精品文档

相关文档