硅铬合金(Chromium silicon alloy)
硅铬合金(Chromium silicon alloy)
EDTA titrimetric method for the determination of aluminium content
1 range
This standard specifies the method, content, reagent, material, instrument and equipment, analysis procedure and calculation result of EDTA titrimetric method for the determination of aluminium content.
This standard applies to the determination of aluminium content in silicon chromium alloy, measuring range (quality fraction): 0.30%--2.50%.
2 method summary
The sample with nitric acid and hydrofluoric acid dissolution, the four generation of silicon silicon fluoride, perchloric acid smoking is exhausted, solution with ammonia separation to remove iron chromium, sodium hydroxide, and then adding an excess of EDTA, on the condition of PH5-6, with PAN as the indicator for titration of copper sulfate standard solution over the amount of EDTA, adding fluoride take sodium aluminum, EDTA and copper sulfate standard solution titration released, according to second times the amount of consumption of copper sulfate, calculate the mass fraction of aluminum.
3 reagent
3.1 ammonium nitrate (solid)
3.2 boric acid (solid)
3.3 nitrate (1.42g/mL)
3.4 hydrofluoric acid (1.15g/mL)
3.5 perchloric acid (1.67g/mL)
3.6 ammonia (0.90g/mL)
3.7 hydrochloric acid solution (1+1)
3.8 sodium hydroxide solution (250g/L) stored in a plastic bottle
3.9 sodium fluoride solution (50g/L) stored in plastic bottles.
3.10 buffer solution: weigh 200g ammonium acetate in 300mL beaker, add 10mL acetic acid (1.05g/mL), dissolved, dilute with water to 1000mL and mix.
3.11 ammonium nitrate lotion (10g/L)
3.12 phenolphthalein (2g/L) with ethanol solution (3+2) preparation.
3.13 PAN indicator (1g/L): ethanol preparation.
3.14 EDTA standard solution (0.01mol/L)
3.15 standard solution of copper sulphate (0.01mol/L)
4 sample
Q/SJFC.J08-011.4-2008
The specimen shall pass through the 0.125mm screen.
5 analysis steps
5.1 sample quantity
Weigh 0.25g sample, accurate to 0.0001g.
5.2 blank test
Along with the sample b
您可能关注的文档
- 电脑高级快捷键使用(The use of advanced keyboard shortcuts).doc
- 电脑植物(Computer Plants).doc
- 电视教材中的二元关系论(Two element relation theory in TV teaching material).doc
- 电脑辐射(Computer radiation).doc
- 电脑题(Computer problem).doc
- 电视剧 步步惊心 影评(TV drama startling step by step ).doc
- 电视机大小与房间尺寸(TV size and room size).doc
- 电视的分镜头教材(Video footage).doc
- 电解槽用部分规格母线生产实践-草稿(Practice of partial specification busbar production for electrolytic cells - draft).doc
- 电视芯片(TV chip).doc
文档评论(0)