日立ypvf故障详解(Hitachi ypvf detailed fault)

日立ypvf故障详解(Hitachi ypvf detailed fault) Hitachi YPVF detailed fault table: TCD14: positive and negative, the power supply voltage error Mastermind (01E6) flag (03E0-4) Deputy head (516C) flag (7180-4) This positive / negative power supply (+/-15V) is important for feeding the operational amplifier, and there is an error to enter the 1C level fault Three TR2 ACR Phase R, 29, +15V (FC23) FF22 220V S 30 38V HC3 Lose T 31, 38V, HC4, --15V (FC25) FF25 Enter 32 HC5 GND (FF20) MPU A, according to the diagram above, we know that TR2 is normal and ACR is abnormal and ACR is faulty. B, there are HCT, RE and RE in PN15 fault may check the wiring plug palette. TCD15: another computer fault A. the main computer is out of order and sometimes the vice computer shows the TCD15 counter running When the B. main computer fails, the number of re starts is recorded on the 66 counter, while the secondary computer counts again at the 5A counter C. business computer failure, restart 58 times the number of counters, and the main computer re record 65 counters D. cut off the power and then connect it to see if the WDT (main or sub computer) has turned off the lights, turned off and turned on, and watched the movement of the computer E., such as numerous, must replace the MPU board F. may also be the noise of the regeneration loop G. regeneration transistor action or wiring break, input to change to noise TCD16: there is a mistake in the main computer operation A. examination showed that the data of $03E9 $47AE $5A12 B. in the short circuit, the main pay computer must be the same, more data from the main computer circuit of $4118 to $411F, $E88010 more computer to $E8801E In the C. for the computer, with constant $501C $501E data, and data decreased D. building height test, EEPROM data input, the operation of the registration data exists, pay computer parallel communication, IRQ (interrupt display) can not be implemented, that is, this fault E. by the counter (see TCD15) to determine the mast

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档