cems维护要求(CEMS maintenance requirements).docVIP

cems维护要求(CEMS maintenance requirements).doc

  1. 1、本文档共7页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
cems维护要求(CEMS maintenance requirements)

cems维护要求(CEMS maintenance requirements) Gaseous pollutants CEMS 1 no more than 15 days with zero gas and high concentration of standard gas calibration device or a calibration instrument zero and span, and check Response time, zero and span drift during this period and the response time should be consistent with the response time: less than 200s. Zero drift (24 hour zero drift does not exceed the full range of + 2.5%) range drift (24 hour span drift does not exceed the full range of + 2.5%. When the ratio (relative accuracy) method for the determination of SO2 and NOx concentration: the average value of A. is greater than or equal to 250 mol/mo (L SO2, NO and NO2 were 715 mg/m3, 335 mg/m3 and 513 mg/m3), the relative accuracy is less than 15%; B. less than 250 mol/mol (SO2, NO and NO2 were 715 mg/m3, 335 mg/m3 and 513 mg/m3), the absolute value of the reference method and the results of CEMS mean value difference should be not greater than 20 mol/mol (SO2, NO and NO2 were 57 mg/m3, 27 mg/m3 and 41 mg/m3); C. less than 50 mol/mol (SO2, NO and NO2 respectively. 143 mg/m3, 67 mg/m3 and 103 mg/m3), the absolute value of the reference method and the results of CEMS mean value difference should be not greater than 15 mol/mol (SO2, NO and NO2 were 43 mg/m3, 20 mg/m3 and 31 mg/m3). No more than 30 days); a linear error test, linear error should be consistent with the linear error: low, medium and high concentration of standard gas inspection, no more than + 5% to determine the relative error value and the reference value of CEMS. No more than 3 months; a relative accuracy test, relative accuracy requirements. 2 no more than 3 months to replace a sampling probe filter. 3 no more than 3 months to replace a purification of the dilution air dehumidification, dust and other materials. 4 must use the standard material in the period of validity. 5 must vent air compressor in the condensed water every day. 6 direct measurement of gaseous pollutants CEMS, and no more than 3 months o

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档