末端试水阀作用与功能(Function and function of end water test valve)

末端试水阀作用与功能(Function and function of end water test valve) Function and function of water test device at the end of automatic sprinkler system The function of academic debate in recent years the water fire sprinkler system end testing equipment more intense [1 ~ 4], the focus of debate is a function of end testing equipment is only in order to test the water flow indicator, pressure switch, hydraulic alarm can open when the action in the nozzle and alarm function; function: two end testing device also has the auxiliary role of the hydraulic state inspection system. Document [1] emphasizes that the terminal water test device has only one function, the document [2] [3] emphasizes that the end water test device has functions besides one, and also has function two. Several norms and Academic Conference on everyones views are not the same, each of its term, testing method and system performance through the function of alarm valve, water flow indicator of different, and the comparison of end testing equipment at home and abroad the schema, that at the end of the system test device, and the water flow indicator alarm valve performance testing and system capacity detection methods, to determine the water supply capacity and system function at the end testing device test. The main difference between the 2 end testing equipment installation and setting end testing device of schema schema there is no pressure gauge, the automatic control function of 2 different settings, the difference between setting only wet system, or closed system can be set up. The United States N FPA end testing device without pressure gauge, emphasis should be set outside the dehumidification system and dry preaction system, only the Chinese specification for end testing equipment should be set in the system the most disadvantageous sprinkler, each fire zone should be set for each layer, but what kind of system should be set no clear rules end testing device with automatic control function, is developed

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档