- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
第12章 典型仪器中集成电路
* * * 第12章 典型仪器中集成电路 集成电路芯片及应用 2011年12月 脉搏血氧计(Pulse oximeters) Pulse oximeters noninvasively measure or continuously monitor oxygen saturation in arterial blood to ensure that there is sufficient oxygenation. Typical applications include people with respiratory problems who are under anesthesia, neonates, and critically ill patients. finger, toe, or ear transmissive optical techniques or reflective techniques. 脉搏血氧计(Pulse oximeters) Functional block diagram of a pulse oximeter Principle of operation Operation is based on the light absorption characteristics of hemoglobin(血红蛋白) in the blood. Oxygenated hemoglobin absorbs more infrared light than red light, and deoxygenated hemoglobin absorbs more red light than infrared light. Thus, red and infrared LEDs in the oximeter alternately transmit light, and a photodiode receives the light that is not absorbed. The ratio of the red and infrared light received by the photodiode is used to calculate the percentage of oxygen in the blood. Based on the pulsatile nature of arterial blood flow, the pulse rate and strength are also determined and displayed during the measurement cycle. 1-Wire memory A unique 64-bit serial identification number store calibration coefficients how many times the sensor can be used before replacement Sensor cable calibration driving the LEDs Photodiode interface low input current input current noise and input voltage noise high-voltage operation. removing the ambient portion compensate for changing environmental factors and the aging of optical components. high SNR and sample rate Ultra-low-noise, high-voltage operational amplifier MAX9945 Low-noise front-end extends oxygen saturation measurement range –– Up to 38V supply voltage –– Low 1fA/√Hz input-current noise –– Low 15nV/√Hz input-voltage noise Increases saturation measurement accuracy –– Low 50fA input-bias current –– 3MHz unity-gain bandwidth –– Rail-to-rail output-voltage swing Enables smaller, lower power pulse oximeters –– 400μA quiesce
文档评论(0)